    No Hot water but central heating is fine.

    Call me stupid but what does a blocked cold feed have to do with hot water? I know what a blocked cold feed looks like I`ve chopped out hundreds. Can you explain how a blocked cold feed on the heating side from the expansion tank, affects the hot water?? I`m stupid I know so can you explain in...
  2. C

    Domestic hot water, NOT HOT!

    sounds like a blocked cold feed to me pop a hose on a drain point and open then have a look top see of the f + e cisterns empties if not the cold feed is defo blocked. start cutting and good luck :wink:
  3. K

    boiler temperature went sky high bleeding rads

    Cold feed blocked where it joins pipework
  4. muggles

    4 plumbers down still not sorted

    Sounds like a blocked cold feed to the cylinder.
  5. ianmcd

    Is this boiler "fault" normal - video

    Google or search on here for blocked cold feed
  6. seco services

    Water noise in central heating

    Poss the cold feed is blocked/restricted. :idea:
  7. Y

    central heating header tank problem

    could be the common blocked cold feed connection
  8. S

    New pump problems

    cold feed blocked, lack of water in system
  9. G

    Ideal Classic Boiler/New Pump/Airlock?

    Header tank dry ? Cold feed blocked?
  10. C

    No heating after bleeding radiators

    blocked cold feed mate, nasty job that
  11. ollski

    Air entering through vent pipe

    Is the cold feed clear? ie not blocked anywhere.
  12. W

    noisy pump

    could be pump. could be blocked cold feed.
  13. kevplumb

    Central Heating Airlock?

    your cold feed is blocked IMHO :cry:
  14. kevplumb

    Possible air lock?

    part blocked cold feed pipe :idea:
  15. B

    No CH after rads replaced...

    ? blocked cold feed ? check using a magnet.
  16. M

    Radiator not bleeding

    CHECK COLD FEED INTO SYSTEM IS POSS BLOCKED.
  17. petit_pablo

    Air in boiler - is plumber giving me the runaround?!

    Possiby a cold feed blocked if it happened after the rad was fitted. Can you drain a bit of water off from a drain point? Turn the water off at stop tap and drain some water off. If the water level in the CH header drops cold feed is ok, if the water level remains constant cold feed is...
  18. G

    Ventpipe in F&E Tank is constantaly running.....

    Blocked cold feed? How's that cause pumping over (not questioning anybody's answer just curious)? I guess that because water cannot expand up cold feed it goes up vent? But surely it would do this for a while and then because no more water comes in via cold feed to replace (because it is...
  19. N

    BAXI BOILER GRAVITY FED - NO WATER SUPPLIED TO PUMP????

    These old systems are prone to cold feed becoming blocked and boiling away the water. Check tank is full of water, if so open rad vent, no water means blocked cold feed. If there is water and pump valves are opened and can push finger in then either air lock or blocked pipes.
  20. K

    HOT WATER OVERFLOWING INTO EXPANSION TANK

    no it can't be blocked as system is pumping over. it would boil dry if cold feed was blocked system has crud in it try draining off as much of the water as possible and refilling then add a chemical cleaner like fernox restorer to the system also worth checking the pipework between open vent...