Search results

  1. P

    Laths v Plasterboard - using professional plasterer

    Originally I had assumed regular plaster could be placed onto laths by a regular plasterer, and if this was the case, it would mean there wouldn't be the extra time/expense of removing laths and placing new plasterboard in place. I now realise this wouldn't be the case.
  2. P

    Oak pattress behind electrical switch

    This is the sort of thing I'm thinking of.
  3. P

    Laths v Plasterboard - using professional plasterer

    So if regular plaster cannot go directly onto laths, and needs to be a lime plaster - so this needs to be a specialist plasterer only? Regular plasterers can't use lime plaster directly onto laths? (In case relevant, the house is not listed).
  4. P

    Laths v Plasterboard - using professional plasterer

    Okay - so regular plaster may not be suitable to plaster over laths; I hadn't thought of that possibility. If any plasterers can confirm? Thanks.
  5. P

    Laths v Plasterboard - using professional plasterer

    Yes - these would be original timber laths already in-situ.
  6. P

    Oak pattress behind electrical switch

    If having an electrician place a surface-mounted wooden pattress box on a wall with a light switch on this in order to achieve a 1930s look, I expect there is some element of increased risk with having a timber product next to an electrical product in this manner. To reduce any such risk...
  7. P

    Laths v Plasterboard - using professional plasterer

    Thanks - it would just be standard builders-merchant's plaster in either scenario.
  8. P

    Laths v Plasterboard - using professional plasterer

    Is it any more expensive/time consuming/difficult for a professional plasterer to plaster over timber laths which are already in-situ compared to plastering over pre-installed plasterboard of the same square area? Thanks.
  9. P

    TRV question

    Quite often TRVs will have vertical openings along the upper section which allow the internal sensor to determine the air temperature. This TRV does not appear to have these. Do you think that might be an issue? Has anyone here used this specific TRV...
  10. P

    Economy button on Honeywell TRV

    Is this "economy button" (the green button) a feature which also appears on other TRVs other than this Honeywell Valencia VTL120? I don't think I've seen it before. Is the purpose of this to easily turn off a specific radiator, without having to adjust the radiator setting on that TRV i.e. it...
  11. P

    2000W electrical heater v Type 22 Horizontal

    One reason I ask is that I've tried a vertical column rad in the past and irrespective of what the official wattage was, it definitely took the room longer to heat up compared to a standalone electrical heater of equivalent wattage.
  12. P

    2000W electrical heater v Type 22 Horizontal

    In reality, do you think a standalone electrical 2000W electrical heater (example below) would heat up a room in the same time it would take a central heating Type 22 horizontal radiator of exactly 2000W (at delta 50, with CH at 50) to heat up the same room? Or would the CH rad heat the room up...
  13. P

    Sizing radiators for condensing / non-condensing boilers

    I think when radiators are sized for a central heating system, the size of rads required for each room would differ depending upon whether the system had a condensing or non-condensing boiler. I'm not sure if the radiators should have greater output capability if its a condensing or...
  14. P

    Difference between Stelrad Vita Deco & Softline Deco?

    Thanks muggles. When I click on the "Play" button to activate the rotational image of each radiator and spin the image around, they both look identical to me.
  15. P

    Difference between Stelrad Vita Deco & Softline Deco?

    Would anyone happen to know what the difference is between these two radiators? I can see that the name is different, and also the price. Presumably something else differentiates them which I have not as yet identified. Thanks! Vita Deco Vertical...
  16. P

    Vertical radiator recommendations

    Noted. Is the mild steel a better material for radiator production than aluminium?
  17. P

    Vertical radiator recommendations

    Out of curiosity, is there any substantive benefit in vertical column over vertical tube, or vice versa?
  18. P

    Vertical radiator recommendations

    https://www.stelrad.com/radiators/vertical-radiators/softline-compact-vertical-1800mm-x-400mm/ Any experience of the above aluminium vertical? Would you have any specifics with regards to installing a vertical Acova in a room as regards to the size of Acova, quantity required in the room and...
  19. P

    Vertical radiator recommendations

    Potentially either, if it had good heat output. I have one 1800 x 470 mm 3-column radiator in a 9 sqm room, and it takes 4-5 hours to get the temperature up to 20/21 C. I had thought this was over-sized when I bought it, but even if it was double the size again it would potentially still take...