Search results

  1. Colin Brenton

    TV man left us with this - how to fix?

    Personally I wouldn't be TOO worried, as long as the white cable has a three pin fused plug on the end - if it's been connected into the back of an existing mains socket that is a bit more of a can of worms. Yes, it's fairly rough, but is it actually dangerous? I'd personally say no, but it...
  2. Colin Brenton

    Shower cable rating

    To answer the question, I'd personally want to get either an RCD or RCBO in place to feed the shower if it were mine tbh. I'll leave cable derating discussions to the other lads ;)
  3. Colin Brenton

    Red Light on Digital Meter

    No power available gives no LED at all. Power available and being used gives a flashing LED. Power available but none being drawn gives a solid red LED. HTH
  4. Colin Brenton

    Wiring problem?

    Sounds straightforward enough. Join the black and brown from the hob flex to the red (or brown) from the switch. Join the blue from the hob flex to the black (or blue) from the switch. Join the green and yellow from the hob flex to the green and yellow (or green) from the switch. Worth...
  5. Colin Brenton

    New circuit for induction hob, rcd tripped off

    Very true, I was bound to forget something :D
  6. Colin Brenton

    What to do with my Frankenstein fuse box?

    I'd be seriously considering at least fairly significant rewiring, to be totally honest. If you've just bought, now is the best time to do it, rather than when you've decorated, had carpets put down etc. That Memette unit looks to be 1930s/40s, to me, connected to rubber covered cabling and is...
  7. Colin Brenton

    New circuit for induction hob, rcd tripped off

    An RCD won't trip on overload, they don't (can't) even detect it. MCBs provide over current protection, the RCD provides earth leakage protection.
  8. Colin Brenton

    A cracked plug socket which I use a lot for fan-heater.

    Easy enough to DIY a replacement. Something like this would be a big improvement. Switch all the house power at the fuse box before starting, and check that it is dead before you start. https://www.screwfix.com/p/mk-logic-plus-13a-1-gang-dp-switched-plug-socket-white/14790 Good luck but post...
  9. Colin Brenton

    Flashing LED’s

    Are they 12v or 240v bulbs? Mad question, but do they flash when they should be on, or when they should be off?
  10. Colin Brenton

    Mysterious built-in "wardrobe" in my bed room. Is these asbestos?

    Looks like a simple-ish job; crow-bar/screwdriver to break up the timber framework. Then strip the wallpaper. Finally patch/replace (or just sand and paint) the skirting if needed, then skim and paint the plaster. As to cost, reckon on maybe half to a day of 'plasterer time', cost depends...
  11. Colin Brenton

    Large white box with Danger 230 volts on it

    Might be a junction box where the consumer unit used to be?
  12. Colin Brenton

    Please help! FTB with eicr unsatisfactory

    To be honest, if you like the house and can get it at a price you're comfortable with, what is in that report wouldn't worry me too much - the obvious thing would be to ask for a price to fix the problems, and ask the person who did the report for more information on what that would involve and...
  13. Colin Brenton

    Spark from immersion heater switch

    Haha, true. Time your blink reflex carefully :D
  14. Colin Brenton

    Spark from immersion heater switch

    See if you can fit a 40 or 50 amp rated (cooker type?) switch into the box. It will be loaded at less than half of its capacity, rather than around three quarters, and will have heavier duty contacts etc. Something like this might be suitable...
  15. Colin Brenton

    Smart Meter Install - fit new isolator before?

    If you've got an isolator fitted into your present meter, why not fit the new one today? That way it doesn't matter if the new meter has one or not.
  16. Colin Brenton

    Swap Oven Socket

    What about this? https://www.cef.co.uk/catalogue/products/149121-45a-dp-cooker-control-unit-with-neon-and-13a-socket-metal-white-flush But yes, agree about replacing the white rubber cable being more urgent!
  17. Colin Brenton

    Electric dilemma - MCB info wanted

    Yep, same here.
  18. Colin Brenton

    Crypto mining electrics

    Basically, GPUs are better/quicker at performing the calculations than normal computer CPUs would be (fairly similar maths to pixel shading type calculations - I think), so they use as many of them as they can.
  19. Colin Brenton

    Crypto mining electrics

    And what about the future of the planet? Or do you consider that that is just "someone else's problem"? FGS!!!!!
  20. Colin Brenton

    Swapping Honeywell T6360 thermostat for Google best e

    I reasonably sure the device you are holding doesn't keep the neutral and earth leads apart, it actually connects them together. Get a second one, and put neutral into one of them, earth into the other, and try it again.
Back
Top