  1. O

    Tap re-seater tool thread type

    I would have thought the 1/2" would screw into that tap. I doubt if it is anywhere near the age of the house. Having said that, I don't know what you paid for the kit, but it would have gone a long way towards a new tap. It looks like someone's had a right fit with that one.
  2. O

    TRV and wall thermostat in the same room, how can it work any other way?

    It all depends on the relative settings of the thermostats. Presumably the wall stat is a full system thermostat and controls the whole system whereas the TRV are specific to one room. Surely the normal set up would have a full system control in a relatively open area, with localised control for...
  3. O

    Thermostat behaving abnormally

    Your pictures of a kitchen tap and cold water pipe do not match your titles
  4. O

    Danesmoore 20/25 driving me mad

    No spark is indicative of either photocell fault, faulty transformer or control box. When the spark fails, after checking the electrode connections and leads, disconnect the transformer lead and check for voltage at the plug. If there is no power then you've probably found the fault. To...
  5. O

    Danesmoore 20/25 driving me mad

    What burner are we talking about, and is it down firing from the top or horizontal from the front?
  6. O

    Oily smell from Worcester Bosch Greenstar Heatslave 2 25/32

    Is this a boiler with a down firing burner?
  7. O

    Filling Loops open or closed?

    The flat sides need to be at 90 degrees to the pipe to be closed. You may find there is no positive stop to the valve if it is a ball that is operated. What do you have at the other end of the filling loop? If that is closed, then it will also stop the flow.
  8. O

    Replacement Greenstar Danesmoor boiler - advice please

    Later boilers 'just out of warranty' of any make do not last as long as their predecessors. The replacement of parts such as photocells or pump coils is a fact of life with any boiler. Whilst the modern control box may give signals indicating faults to be told 'no flame detected' is not...
  9. O

    Old Worcester Heatslave 15/19 (Red light) Not working

    Is it the red light on the control box? Have you tried pushing it? That is a very old burner and if the control box has failed, whilst it is possible to replace with a newer box, you may be halfway to the cost of a complete new burner.
  10. O

    worcester heatslave 15/19 - How to Bleed Advice

    Don't forget you may have in line filters fitted that will also need bleeding. Follow the oil line from the tank all the way to the burner to check for other bleed needs.
  11. O

    Oil boiler not firing any ideas?

    Have you pressed the reset button on the control box on the burner?
  12. O

    Riello pump pressure test

    What model burner do you have? The pressure port usually used is the conveniently placed lower hexagon screw below the pressure adjuster. What problems do you actually have?
  13. O

    Riello pump pressure test

    With the greatest respect, asking a question such as this does suggest you should not be messing with your burner.
  14. O

    Heatslave 20/25 diverter valve problem.

    Consult the manufacturer's instruction easily available on line. This valve differs from many.
  15. O

    Height of oil tank from ground for gravity feed?

    Basically it needs to be above the height of the burner but as Muggles says, on a long run or one with many turns, a larger bore pipe may be needed .
  16. O

    Baxi Bermuda 552 Replacement Ignition Switch

    Maybe the reward for a return trip coupled with the low cost of the part would not be sufficient for the job. I doubt you would be happy with a £50+ bill for the repair.
  17. O

    Worcester bosch heatslave 12/14 oil pump pressure problem

    If the burner fires before the control box initiates the solenoid then it will lock out as a false flame. It would appear that the solenoid valve is passing as when you turn pressure right down it operates correctly. Clean out the solenoid port and if it still fails, replace the pump.
  18. O

    Boulter Camray 5 repeated stop/start cycle

    Is this a combi or heat only boiler? Either way I can't see it being a timer/programmer problem, but more a control/DHW thermostat OR a circulation problem within the system.
  19. O

    Riello G5X Burner

    There is a flange gasket that may have degraded over time. More often though the leak is from the access panel or flue connections. With an analyser, the source of the leak is soon identified.
  20. O

    log burner and CT1 silicone

    Can you not use fixings on the inside of the brackets? They would be less intrusive there.