Search results

  1. M

    Installing AG6 BellBox to Accenta Mini G4 Alarm

    Hi, I am currently installing an Intellisense AG6 bellbox to a Honeywell Accenta Mini G4 system. I just want to double check the wiring of the bellbox. On the Alarm control panel is have the connections: BELL - BELL + STROBE - SCB T SCB A On the Bell Box I have: ST - R - SW - V + V - How...
  2. M

    Cutting / Adjusting Mira Agile ERD mixer shower.

    Mira have already replied, saying that the pipe is 19mm in diamter! Maybe if it's more like 19/20mm, could use 22mm chrome pipe and 22mm chrome couplers with A LOT of PTFE tape on one side of each coupler?? OR 20mm stainless steel pipe and 20mm MDPE white compression couplers. Which won't look...
  3. M

    Cutting / Adjusting Mira Agile ERD mixer shower.

    Hi, Thanks. Yes i accidentally posted the wrong photo, as i just searched for a photo of an Agile on google and didn't notice this wasn't an Agile photo. Thanks, yes a proper extension kit would be best!!!
  4. M

    Cutting / Adjusting Mira Agile ERD mixer shower.

    Hi, thanks for the reply. I will measure myself, but also ask the manufacturer for measurements. Yeah a chrome compression fit or push fit may indeed be easier. I know this will probably void the Mira warranty also!! Thanks
  5. M

    Cutting / Adjusting Mira Agile ERD mixer shower.

    Hi, We have a new Mira Agile ERD mixer shower, this one: However, we are intalling it over a Bath and we have a very large bath, with significant sloped sides. The overtop deluge head only sticks out from the wall by 520mm total or 420mm to the centre of the head and this won't quite...
  6. M

    My Consumer Unit and RCD

    Hi, ok thanks. What is the main advantage of RCBOs? Is each like a combined RCD and MCB for each individual circuit?
  7. M

    My Consumer Unit and RCD

    Hello, The house that we have bought has a CU that was last tested in 2016. It has a 100A supply Main Switch and then a single 63A RCD that protects 7 x MCB: 1 x 40A Shower - 10mm Cable 1 x 32A Cooker - 6mm Cable 1 x 32A Ground Floor Ring Main - 2.5mm Cable 1 x 32A First Floor (small) +...
  8. M

    Accenta G4 Mini Alarm - intermittent False Alarms

    Hi, I installed an Accenta G4 Mini alarm system myself over 1 year ago. The system has 2 x LCD keypads, 1 x external siren, 1 x external dummy, 1 x internal siren, 3 x door contacts and 5 x pet tolerant PIRs. All has been mostly fine for over 1 year, but recently we've had a couple of false...
  9. M

    Constant Tamper Fault on Honeywell PIR

    Hi, Zone 3 is in the middle of the house (living room). All externals doors have contacts and there is no way to get to that without passing other rooms / PIRs. So F doesn't mean fault??
  10. M

    Constant Tamper Fault on Honeywell PIR

    Yes it is saying exactly that
  11. M

    Constant Tamper Fault on Honeywell PIR

    1234678 TP 00F0000 00 Yes it is saying this
  12. M

    Constant Tamper Fault on Honeywell PIR

    Hi, I have looked on the system Log again, and maybe i was wrong. If is saying "F" under zone 3 and everything else including TP is set at 0.
  13. M

    Constant Tamper Fault on Honeywell PIR

    Hi, The whole installation is only 12 months old and have an X-large 12 month old battery.
  14. M

    Constant Tamper Fault on Honeywell PIR

    Hi, Thanks for your reply. I know it's one specific PIR, as the keyboard says Tamper Fault Connection #3 on the screen. Connection #3 is a single PIR. The false alarms have always been either Connection #3 and #5 which are both internal PIRs. We've never had faults with either keyboard or...
  15. M

    Constant Tamper Fault on Honeywell PIR

    Hi, We have a Honyewell Accenta G4 system setup in our house with control panel, 6 x PIR and 3 x door contacts. A few months ago we were having occasional issues of two of the PIRs setting off the alarm with a tamper fault. I checked ALL of the wiring on both the PIR ends and the Control Panel...
  16. M

    Vaillant Boiler burner always very low for CH

    Hi, Thanks. Yes you are correct this is it. I have just heard back from my Plumber and he also said that it needs taking off the Auto setting and that he will come around to adjust the settings to a manual KW setting based on the house / rads. Thanks for your reply.
  17. M

    Vaillant Boiler burner always very low for CH

    Hi, We had a Vaillant EcoTec Plus 832 + Rads + Filters + Plumbcentre Thermostat all installed recently. This issue we are having is that the burner never goes into high gear, it always stays super low (on the buner scale) and rads take 1 hour to get fully hot. I have read that these boilers...
  18. M

    My Domestic Wiring

    I now have 3 x quotes of £120-150 to inspect and test all of my wiring and the Consumer Unit and provide a certificate if it all passes.
  19. M

    My Domestic Wiring

    Hello Deadshort, Thanks for your response. I will indeed get it properly tested very soon by a proper electrician. I was just looking for constructive advise / criticism in the mean time, which you have provided. Thanks
  20. M

    My Domestic Wiring

    One other point that i forgot to mention. The house had been previously fully wired up by a proper sparky in 2013. When i gutted and demolished the house and took off the entire roof structure, i made note of all the electrics and exactly how they were done. I also took tonnes of photos. The...