  1. L

    Extension reroofing

    Thanks. The britmet pantile 2000 quote was actually more than epdm. £2180 vs £1800. I am a bit concerned about epdm on a 'cold' roof as it can cause condensation on the rafters if heat can rise above the insulation. Would it need to be converted to a warm roof with the insulation on top of the...
  2. L

    Extension reroofing

    Thanks for the advice. I have looked at epdm but have seen issues with it lifting. Would putting an osb deck on the rafters cause a problem if it is a 'cold roof' with the insulation in the rafters? Definitely avoid the tile sheets?
  3. L

    Mira advance thermostatic cutting out after a few seconds

    That's the concern! Whether to spend money and throw parts at it. We have an older used mira which we're checking the part number on the flow valve. It's one of the older ones with the memory settings.
  4. L

    Mira advance thermostatic cutting out after a few seconds

    Thanks for the reply. I did think this but the water in the area is soft.
  5. L

    Mira advance thermostatic cutting out after a few seconds

    Hi folks, we have a 2014 Mira Thermostatic advance shower. Once turned on, it will stay on for a couple of seconds, then low pressure and service lights both illuminate and stay on. It will then shut down. Is the fault likely to be the flow assembly? My father said the filters are clean on...
  6. L

    Extension reroofing

    Hi folks Any advice would be good. Has anyone used the britmet pantile 2000 sheets? Would they give too much noise off in heavy rain etc?
  7. L

    Extension reroofing

    Hello folks. Looking at roofing options for the kitchen extension. It's a 10 degree pitch, currently it has marley concrete tiles on which are incorrect of course. What roofing type would you recommend? Had a few quotes for felt/epdm/ metro tiles so far. Thanks for any input. I'm interested...
  8. L

    Suprima kettling?

    Thanks for the reply, nothing obvious around those pipes at all. I should mention the 'coolant' is also clear when I added the X200.
  9. L

    Suprima kettling?

    Hi folks I have a '98 Suprima 40 and hot water cylinder (3 port valve), after approx 5 mins from cold and selecting hot water I get kettling symptoms (some fizzing/mild clonks) from about 60c to 70s. I have measured the temperature on the outlet with an infra red thermometer & the thermistor...
  10. L

    Suprima kettling?

    Hi folks I have a '98 Suprima 40, after approx 5 mins from cold I get crackling and popping from the boiler when its heating up. After another 10 mins or so it changes to more of a hissing sound like when a kettle is boiling. The actual fluid is clean, I have added 1l x200 via the bathroom...
  11. L

    Potterton Suprima - controller fault?

    Thanks for the reply, any obvious candidates?
  12. L

    Potterton Suprima - controller fault?

    Hi folks, not my boiler but by proxy I can hear it through the wall! Every few mins I hear the boiler try to start up about 5 times, this can last between a few seconds or usually about 20-30 seconds. This starts about 10pm usually when the heating goes off and lasts all night. Does this...
  13. L

    Suprima fan differences?

    Yes the new fans come with the back plate seal and got 2 new outlet seals as they can dry up, just astounded at the quality between the 2 fans, im wondering if 2 points of location would also be adding to the noise through the cavity wall. Both are Suprima 40 models too.
  14. L

    Suprima fan differences?

    Its driving me bonkers, and their boiler keeps trying to start up and then stops, assuming the PCB
  15. L

    Suprima fan differences?

    Hi folks, Has anyone had experiences with the Sifan fans for the Suprima boilers being noisy? My neighbour has one (2 screw type), mine is the original ebmpapst one (3 screw), these seem much higher quality so I'm going to try and get one fitted next door as well as renew mine as next doors...