  1. G

    Baxi 105e fan/flue fault

    Why not call Heateam the service division of Baxi! They offer a fixed price repair with no hidden extras and it comes with a years warranty if anything else goes wrong! :lol:
  2. G

    potterton promax 24 he problem

    I agree with Gordon as it does sound like door seals! Merry Xmas!
  3. G

    Baxi combi 133he plus Combustion window

    Yes they run orange! But please be careful when changing gas carrying components for yours and your families sake ;0)
  4. G

    Potterton Suprima 30 and Boilermate II

    Oh ok then it could be the pcb that's faulty there were some early ones which did do this after a while! Basically check the flow temperature with the boiler on max! (as it should be for gledhill!) you should be getting around 75-80 degrees! If its any less than 70 you will need to fit a new...
  5. G

    Potterton Suprima 30 and Boilermate II

    Is it the new style pcb with 1 light or old with 2?
  6. G

    Potterton HE Combi boiler

    Peter check you haven't left the filling left on! Pressure should be around 1 bar when systems cold! If that's all ok and pressure still rises and water still goes out O/Flow then there's a good chance the expansion vessel either needs repressurising or is fooked! :roll:
  7. G

    Baxi duotec combi 28 he showing error e119 with pressure??

    There's a drain off just to the right of the pump at the bottom of the boiler!
  8. G

    best boiler update

    Yes there good too! :lol:
  9. G

    Baxi duotec combi 28 he showing error e119 with pressure??

    Make sure gauge is above 1 bar! If it still won't reset then it's good chance the pressure switch is blocked or knackered! Drain boiler then unscrew the pressure switch it's the black plastic round thing with 2 blue wires going to it! Clean out the small hole of any debris and refit and refill...
  10. G

    best boiler update

    Remeha Avanta Plus combis are quiet! Reliable! Small and have great performance :lol:
  11. G

    potterton puma 100e too hot ?

    Sounds to me like the expansion vessel hose is blocked! :roll:
  12. G

    Range Powermax 155x - HW works but not CH

    Impeller has probably dropped off heating pump!
  13. G

    Baxi 105e no heating

    Does sound like pcb! Probably dry joint on it! :roll:
  14. G

    Baxi 105e no heating

    If there is definately power to the switched live and the heating neon isn't lit and the selector switch is in hot water and heating position then it can only be either the selector switch or the pcb that is faulty! :roll:
  15. G

    baxi genesis 80

    Sounds to me like the 3 way valve! Probably sticking!
  16. G

    Honeywell ST9400C

    Have you tried the reset?
  17. G

    Baxi Combi 80E. hot water not constant

    You can clean it out but wouldn't be 100 percent! Better to replace it :lol:
  18. G

    Baxi 105e Intermittant Hot Water problems

    The clue is in what the temperature lights on the boiler are doing? ............?
  19. G

    Potterton Performa 28

    When they put the new pcb in they MAY have not put the thermostat control knobs back on correctly and thus stop the pcb from being turned up high?