Search results

  1. I

    Modular Griddle

    Hi, Going back quite a few years but purchased two restaurant griddles for use on a mobile catering unit (changed the included LPG jets) and need to get hold of a servicing manual. The make is Modular and I did hear that they were possibly French, they were quite a few around at the time...
  2. I

    Ideas on where to tile to regarding shower area perimeter

    Hi, Thought I may get some ideas here......I want to tile just the shower area within the bathroom and wondered where to finish the tiles in regard to the shower cubicle sides, I have seen showers tiled to the width of the tray but this leaves an inch or so showing on the outside of the...
  3. I

    What Tile Adhesive On Aquapanel

    Thanks for that, would I need to use a flexible grout?
  4. I

    What Tile Adhesive On Aquapanel

    Hi, Could anyone tell me what type of tile adhesive to use for tiling in a shower with a Aquapanel backing, obviously it has to be a waterproof adhesive but was not sure what kind, flexible etc, many thanks, Also any one know how to cut circular holes in tiles, I have an electric wet tile...
  5. I

    A1 AJ600 Alarm Problem

    Yes, but i did not realize it does allow you to set walk through zones, I will rewire the alarm to 3 different circuits as you suggest, 1 entry/exit 2 walk through (in view of entry) 3 standard. I think from what we have discussed it will most likely be a faulty pir, I have spare ones...and...
  6. I

    A1 AJ600 Alarm Problem

    Found maual online at http://www.guardianalarms.net/home_security_manuals/A1_Home_Security/AJ600N_Installation_Manual.pdf I thinks its pages 12, 13, 14, that shows the wiring for more than one pir per circuit!
  7. I

    A1 AJ600 Alarm Problem

    I see what you are saying, can you set more that one circuit to be entry/exit though.....this would be the problem as more than one pir could sense movement on entry. I could scan the manual maybe to show you tomorrow
  8. I

    A1 AJ600 Alarm Problem

    Not according to the installation manual....why would this be, the alarm does not arm on exit while sensors are active?
  9. I

    A1 AJ600 Alarm Problem

    Sorry thought you meant a sensor in general!
  10. I

    A1 AJ600 Alarm Problem

    Well, you could be right there, the set up was 2 pir sensors on zone 1 (entry/exit zone) and 1 pir sensor on zone 2.....the 2nd zone was the zone setting the alarm off as far as I can remember......I then moved the pir sensor from zone 2 to zone 1, so all 3 pir sensors on zone 1. I thought this...
  11. I

    A1 AJ600 Alarm Problem

    Hi, I know that these alarms are not the dearest on the market and getting on a bit now but I have fitted three in the past no problems. I had a new spare one which I have recently fitted to my games room, the problem I have is on exit, the exit is fine within the setting time period and...
  12. I

    Pressure Equalising Valve

    Hi, Does anyone know if the Greenstyle make of PEV is of a good quality and also the pressure that it can handle! Many thanks
  13. I

    CWT By law kit

    Thanks GasMan 1965 Balenza seems to think that it should not siphon at all! Could anyone else confirm that it definitely should syphon!
  14. I

    CWT By law kit

    I suppose I was thinking that once a syphon situation had initiated, the water level would syphon below standard level which would allow the mains water to enter the tank causing a continous syphon situation, providing of course that the mains coming in could keep up with the syphon! (unlikely I...
  15. I

    CWT By law kit

    Is it a problem to let it syphon past the set water level of the ball valve or should the dip tube be cut to syphon....but not as much as the water level, in other words should the dip tube dip into the correct water level or just above? Many thanks
  16. I

    CWT By law kit

    Hi, Could anyone explain the idea of the dip tube on the overflow that comes with the by law kit for the cold water tank? I have just found out that when testing an overflow situation, it syphons the water level down past the correct water level. What would be the correct setup for this...
  17. I

    Upgrading From Sky To Sky +

    Hi, I know you do not have to pay the £10 to sky for the Sky + anymore but can you purchase the parts private and do it yourself, or do sky have to do it, do they have do do anything their end, or do they have to upgrade your sky card? Just that it would cost approx £160 to have Sky do it...
  18. I

    Flux !!!

    Hi, Can you use the older type powerflow flux for lead solder for the new yorkshire lead free fittings? Many thanks
  19. I

    Pressure Equalizing Valve

    No problem, thanks very much and appreciate the advice.....it's unbelievable really that you can have a doubt or issue about something one minute with expert advice along with a solution the next !!!