Search results

  1. P

    Push button toilet !

    Sorry another quickie - got a toilet leaking water into pan slowly but continous - it's a push button cistern - can I put a new valve in (Wirquin one looks ok) - as not sure what original valve is....? Think it's 1 1/2" outlet but will wirquin drop valve be ok ?
  2. P

    Common boiler faults guide

    will they just give info over phone? I have been working as an installer with a company and would like to switch over to breakdown and service side. I have doe heating repairs but want to get better. I have been on a few MI courses and read a lot of manuals but just wondered if there were any...
  3. P

    PRO COMBI BOILER NO HEAT OR WATER NOT FIRING

    are there any fault codes showing up on the display? when you open a hot tap does the boiler start and then stop? any noises?
  4. P

    Common boiler faults guide

    yeah I have MI but we all know certain boiler's have common faults and MI don't show them! or mention them!
  5. P

    Common boiler faults guide

    Hi all is there any guide/booklet you can buy that indicates common faults on particular boilers? For example, common faults on Potterton Surpimas, etc etc?
  6. P

    5 year old BIASI M96.24SM/C "Luke warm water"

    when the boiler goes cold does the flame go out and then when left running does it go hot again? (flame lights again)?
  7. P

    5 year old BIASI M96.24SM/C "Luke warm water"

    could be DHW plate heat ex mucked - DHW thermistor, gas settings incorrect, flow rate incorrect or divert valve letting by (proved ok by OP though) could also be DHw flow switch sticking
  8. P

    No water from bathroom cold tap

    well people annoy me ! why not just call a plumber out to do the job in first place!
  9. P

    Glowworm Combi Boiler - Hot Water problem

    could be taking a while to drain the cold in the pipe before the hot comes through - could also be other things!
  10. P

    Glowworm Combi Boiler - Hot Water problem

    what make is it mate? I mean what Glowworm boiler is it/
  11. P

    Potterton Puma 80

    sounds like non power to boiler in CH mode - need to check with a multimeter! whatis CH set to on boiler as well (has it been adjusted)?
  12. P

    Ferroli F30 Pressure Loss

    have you got automaric air vents anywhere in your system?
  13. P

    No water from bathroom cold tap

    sound like an airlock - all that water is wasted why didn't you bung the system? have you got no gate valve on your cold distribution pipe?
  14. P

    Baxi Solo 2 40 PF Luke Warm Water

    what a load of rubbish sounds like either a) system sludged up/needs a clean b) pump is on way out or possibly pump valves furred up or c) gas pressures/gas rate incorrect (RGI jobs) if fan is at fault - test resistance of coil and free running of fan (gently) motorised valves - can...
  15. P

    Halstead ACE HE 24 Locks out unless the front panel removed.

    it is not good to fire a boiler with the casing removed
  16. P

    combi boiler hot water question.....

    just a quickie - can a faulty pcb cause the hot water to run cold and still allow the heating to work ok? if so, how? :oops:
  17. P

    Thermistor change question

    Hi I have a faulty thermistor on my boiler and am wanting to replace it. It;s a Worcester Junior 28i combi Basically I wondered if there's a universal thermistor I could order / get from somehwere, or would I need the exact model number for this boiler? Secondly, I'm wary about...
  18. P

    Gas valve question

    I know someone would say that! I was just wondering what the fif was!.
  19. P

    Gas valve question

    Hi On a gas valve (in a boiler) the older type had standard, diaphragm type (possibly could be range-rated) - but a lot of newer ones have modulating gas valves - where more or less current to the modulating solenoid opens/closes the gas valve more or less, as required.... basic question...
  20. P

    New hot water cylinder question - hemp or ptfe/compound.....

    kev - what do you mean "dow corning"?!!! chrisR - I have used loctite tape before worked ok - do you mean use it on te doughnut or on the wingnut? what do you mean when you say "backed off" - sorry fi I sound dumb today :)
Back