Search results

  1. B

    Best way to wire 6mm cable for induction hob and oven in different location

    Hi all, I have an oven and induction hob that are about 2 meters apart. I have a 6mm cable supply on a 32amp mcb. What is the best way to wire up both oven and hob on the same 6mm cable? Getting a fitting for 6mm cable that will allow me to split it for both seems to be a problem.
  2. B

    Horizontal boiler flue on a pitched roof

    Thanks. It seems this is the one I need...
  3. B

    Horizontal boiler flue on a pitched roof

    Hi, If boiler is in the loft is it possible to have the flue exiting horizontally. Or does it then need to have an elbow attached to make it vertical? All the tile roof seals I have seen are for vertical flues. Cheers.
  4. B

    1 switch controlling all spot lights, another only 4

    Thanks for the replies and discussion chaps. Have decided to keep it simple and have 1 more lighting options by having 4 of the lights that I want on one switch, the other 4 on another. If I want all 8 on I can press both switches, and if I want the other 2 combinations I can switch those...
  5. B

    1 switch controlling all spot lights, another only 4

    Hi, Have tried searching on the forum, but can't find what I'm looking for. Maybe not searching for the right thing! Anyways I want to have 8 spots lights in my living room controlled by one switch. So one switch will turn all 8 on. Then I want to have another switch which will turn only 4 of...
  6. B

    Can UFH zone value be near boiler or needs to be near manifold?

    Cheers Dan. As Ive already got it ill see how it goes with the standard and replace with the proper one if it seizes up as you say. In regards to extending the zone value cable..will 0.75 heat resistant cable be ok or 1.5?
  7. B

    Can UFH zone value be near boiler or needs to be near manifold?

    Thanks Dan. Ive already bought a standard honeywell 2 port valve. Will it not work with this? If the 2 port value is in the loft where the boiler is and the ufh manifold is on the ground floor is it permissible to extend the zone value cable via a junction box to the manifold where its wiring...
  8. B

    Can UFH zone value be near boiler or needs to be near manifold?

    Hi all, Where is the zone value for an UFH system normally installed? Current setup is an S plan,making it into an S plan plus, so additional zone value for the UFH. Where is the best place for it? Cheers.
  9. B

    Putting insulation on top of wooden boards on solid concrete floor

    Thanks Woody, will do as you propose. Cheers.
  10. B

    Putting insulation on top of wooden boards on solid concrete floor

    They are about 3 inches deep and have been set into the concrete. And yes the timber boards on top are flush with the concrete. They have been nailed/screwed through to the sunk in wooden joists.
  11. B

    Putting insulation on top of wooden boards on solid concrete floor

    Thanks chaps. Theres no DPM beneath the existing slab. I don't think I'll take the risk! The wet underfloor heating and screeding is a costly job so not going to risk there being problems in the future and having to rip the whole thing up. Cheers.
  12. B

    Putting insulation on top of wooden boards on solid concrete floor

    Thanks AronSearle, Do you think there will be any issues with the board rotting/condensation due to lack of air?
  13. B

    Putting insulation on top of wooden boards on solid concrete floor

    Hi, I have a solid concrete floor, with joists sunk in the concrete, on top of which 22mm pine boards are screwed to, pre 1930's property. I'm doing underfloor heating, 75mm celotex, then 75mm screed on top. Can I put the celotex directly on top of the wooden boards with a dpm underneath, or...
  14. B

    Wiring Heatmiser wiring centre to Vaillant 630

    Im going to have 5 actuators on my manifold so was advised this is the one I need.
  15. B

    Wiring Heatmiser wiring centre to Vaillant 630

    Brilliant thanks. Wondering if you can help on this too... I have neostats for the the UFH downstairs. I also have bought one for the upstairs radiators. Also have a neostat HW for the DHW. Is UH3 specifically for the UFH only? Im assuming the upstairs rads do not wire into the UH3? Are...
  16. B

    Wiring Heatmiser wiring centre to Vaillant 630

    Thanks. It's an S Plan plus system. 3 zone values. Upstairs heating, DHW and UFH (for which zone value is yet to be added). There is one wire from RT 230v, going to the megaflow junction box. The DHW and UFH have orange wire connected to this. So assuming this is the switched live. Is this...
  17. B

    Wiring Heatmiser wiring centre to Vaillant 630

    The boiler has a connection called RT. I am trying to wire the UH3, the heatmiser wiring centre. It has a connection in there "Boiler" with an "in" and "out" connection to be made.
  18. B

    Wiring Heatmiser wiring centre to Vaillant 630

    Hello, I've got a Vaillant 630 boiler and trying to wire up a UH3 heatmiser wiring centre. Not sure where to connect the Boiler "in" and "out" on he UH3. Anyone familiar with the 630 connections? Have an 24v = RT with a link wire going across it atm. Is this the one the connections need to...
  19. B

    Boss trap into 4" soil pipe - Can it be buried in concrete?

    Hi, Am doing a wet room. Soil pipe for toilet has been run. I'm planning on connecting the shower and basin waste to this pipe using a boss strap fitting. Is it OK to bury the boss trap connections once they have been made? Will this be ok with BC? Thanks.