    Need to cover a vent in a 4rth floor flat without scafolding

    Thank you for all the replies. The one from the prince of darkness could be useful.
  2. L

    Need to cover a vent in a 4rth floor flat without scafolding

    A cooker hood has to be connected to an existing hole of around 10 cm diameter. It is not easy to tidy up the wall from inside. For this reason I am looking for a cap that can be fitted to the tube that will connect to the the cooker hood. My hope is to find a cap that is in some way...
  3. L

    Need to cover a vent in a 4rth floor flat without scafolding

    I am trying to find a fitting to cover an external vent fitted from inside a flat, and without using a scafolding. I am thinking of something that functions like the Rawlplug Spring Toggle used for plasterboards. The idea is to be able to push the vent thru the hole on the wall, and...
  4. L

    Efficient Electric boilers

    If electric boilers are 100% efficient at the point of use, does it mean that for a 2 bedroom flat, with only one shower, it is not necessary to have an storage heater as well?
  5. L

    Efficient Electric boilers

    The cost of bringing gas to my property and installing a central heating system is prohibitive. I am considering alternatives. I would like to be able to remove the internal cold water tank and the imersion heater and install instead an efficient electric boiler instead. is there one you...
  6. L

    Cost of installing gas central heating

    I live in the top floor of a four-floor storey building. The flat will be completely refurbished and I am trying to decide on options. At the moment there is no gas supply to the flat. Do you have idea on costs for bringing gas to the flat (scaffolding, meter, etc) a new boiler 4...
  7. L

    Electric capacity- Fuse box

    Thank you all for your replies. The flat will be refurbished completely, and this includes rewiring, and replacing the fuse box. I have checked with some neighbours and found they had no problem with the supply.
  8. L

    Electric capacity- Fuse box

    I am most grateful for all the replies, particularly for the one from Plugwash. I was hoping that the solution to my problem would be simply to change the board to one similar to those shown in the pictures. It seems I could be wrong. Please confirm.
  9. L

    Electric capacity- Fuse box

    Thank you for the information
  10. L

    CHANGE OF USE OF WATER HEATER CUPBOARD

    Many thanks for the reply. The flat is on third floor of a small building. Since there is a very large water tank in the loft, residents in flats like mine have removed the small water tanks from their flats. Some of them have gas boilers and others water heaters placed on a platform, leaving...
  11. L

    CHANGE OF USE OF WATER HEATER CUPBOARD

    I am planning the refurbishment of my flat and wish to replace a small water tank and a large immersion heater with a small immersion heater and a washing machine below, as show in the photographs. Washing machines are around 82 cm height, and the space inside the cupboard, from floor to...
  12. L

    Electric capacity- Fuse box

    I am planing to refurbish my flat and need to know if my fuse box fits my new electrical requirements. The label in my fuse box reads: 240 VAC 60 ADP 30 matrip As the pictures show the number of fuses are as follows: 5A - 3 15A - 2 30A - 4 45A - 1 I am planing to install 1 oven 1...
  13. Fuse box

    Fuse box

  14. Fuse box and meter

    Fuse box and meter

  15. Fuse box

    Fuse box

  16. L

    Pump Salamander series 119477 not working

    Thank you for your replies. The pump was installed around 5 years ago. It performed properly until recently. I do not believe the fuse was ever an issue. Hence I had no reason to check the fuse box until now. There I found, and replaced, a 13 Amp fuse. I am happy to follow any advise you...
  17. L

    Pump Salamander series 119477 not working

    Thank you for your replies. Following the first advice I have changed the fuse (13 AMP), but the problem with pump remains. Any other suggestion?
  18. L

    Pump Salamander series 119477 not working

    Thank you for the reply. The fuse connection is as shown in the photo. I have just checked for fuses in the local shops and they produced 2, 3, amp fuses. Do I need to buy a 20 amp fuse?
  19. L

    Pump Salamander series 119477 not working

    I have a shower pump Salamander series 119477 Wed 9-09 Pearl 50-Twin 230 V 50 Hz 20 Am For some reason water presure in the shower (cold or hot) was minimum. I do not know what I should check. If the pump has to be replaced, could you please give me some idea of cost of pump and...
  20. L

    Central heating system switch does not work consistently

    I will change the programmer / timeswitch