  1. A

    Potterton Kingfisher2 CF80

    http://www.partsarena.com/baxi/System/index.htm It just shows O rings DIO, no nipples.
  2. A

    Potterton Kingfisher2 CF80

    Thanks bp. would you suggest renewing the tie bars? Do these need to be tightened to a specific torque?
  3. A

    Potterton Kingfisher2 CF80

    I cant see where it's coming from. It's dripping down onto the burner. It may be one of the O rings between the sections. However, I'll need to remove it and pressure test to prove this. If one of the sections is leaking then obviously this work will have been in vain, something I'm trying to...
  4. A

    Potterton Kingfisher2 CF80

    Anyone know where I can get a complete H/Ex (Part No 204382) for this leaking boiler? Tried the usual but as it's obsolete according to Interpart no ones got one. New boiler would mean new position and plenty of headaches. Besides, system piped in barrel so don't really want to put in a...
  5. A

    what is this ? looks like a pressure meter ? wire is cut off

    Pressure vessel for negative head pump. Probably.
  6. A

    Vokera Option

    Anyone had any dealings with one of these cheap and nasty beasts. Went to one today that gave the symtoms of a blocked primary h/e. I assume as the h/e is common to both heating and hot water (as with the Lynx) a summers worth of heating the hot water has baked any crud solid inside the heating...
  7. A

    alpha

    Had a within guarantee visit from an Alpha service tech the other day and got talking to him about the diaphragms on the CB range (wasn't you Paul). He told me that it was a false economy to change just the diaphragm as you you can't be sure that anything else needs changing. He said he always...
  8. A

    Anyone heard of this lot?

    Got a cold call on Friday from someone claiming to be from 'The national heating contractors register' asking if I could take on loads of boiler installs in my area as they are getting three or four calls a week from potential customers. 'I may be interested' I said 'send me some info'. Er, we...
  9. A

    Potterton Performa 28i

    Thanks for all your replies. New PCB was indeed needed. Spent 35 mins on hold waiting for Potterton technical.
  10. A

    Potterton Performa 28i

    Thanks for your rapid replies. The fan light is lit. Forgot to mention I've checked the venturi and the pressure tubes. The flue is also clear.
  11. A

    Potterton Performa 28i

    Visited the above six year old boiler on my way home tonight so didn't have much time to spend on it. Boiler won't fire (though customer says it does occasionaly). Pump runs but fan 'hunts' (slow/fast/slow/fast) APS appears ok. No gas at burner. Any ideas would be appreciated as I can't face...
  12. A

    Glow-worm cxi

    Thanks Gasguru.
  13. A

    Glow-worm cxi

    Just had a customer ring stating that their cxi 30 is leaking. From what I can gather off them it's coming from the little spout on the reduced pressure zone valve. Is this a common fault? Are they prone to leaking?
  14. A

    BG boiler salesman - and Vaillant boilers

    Not sure about Baxi and Vaillant being the same, but Glow-worm and Vaillant are pretty much the same. BG used to sell a rebadged Glow-worm (may still do) under their own name. Get some quotes from some local CORGI installers and you'll knock at least a grand off BGs price. You'll get the same...
  15. A

    Double Glazing FAQ/help.

    We've just been Quoted EIGHT AND A HALF GRAND for ten windows from Anglian. And that includes their current three windows for the price of two. (This is misleading though, as they count a pane of glass as a 'window' not the whole frame) Beware!
  16. A

    Boiler buddy or Magnaclean?

    Magnaclean for me. Don't bother with an in line scale reducer as they don't work. Down here in Sussex the water is very hard and i've never fitted any such device on any of the Alphas i've fitted. Alpha say you don't need one and guarantee the plate exchanger for six years. Apart from what WB...
  17. A

    Is my plumbers advice correct- Faulty Central Heating System

    X400 is mearly a 'suspention agent' not an aggresive cleaner. Better than nothing, just.
  18. A

    Apollo 15/30 Boiler

    Does the pump continue to run after the boiler has shut down? If not then maybe a problem with pump over run. (This dissipates heat from boiler when shut down)
  19. A

    Ocean Alpha 240E - HW Cutting Out

    http://www.diynot.com/forums/viewtopic.php?t=63541&highlight= Try your sensors first.
  20. A

    Alpha 240E intermittent HW / Anyone have a manual?

    Common problem with the 240 and 280 Alphas. It's usually the hot water sensor but sometimes the primary one.