Search results

  1. S

    nvq qualification

    hi i did a level 2 tech cert a couple of years ago. I was looking into the fast track method and almost went down that route before calling my local college who convinced me that their way was the way to go and how could i possibly learn everything in 6 weeks etc etc. So i did the college...
  2. S

    central heating not shutting off

    Oh ok lol yea a plumber then cheers
  3. S

    central heating not shutting off

    Oh right I'll let him know so he can get an electrician to have a look
  4. S

    central heating not shutting off

    Hi i have a friend who has just moved into a new house and he has found a problem with the heating. He has a loft conversion and has 2 zones for heating (downstairs and loft conversion) and says that it is a pretty new installation probably 12 months old or so. He doesnt know who installed the...
  5. S

    economy 7 horstmann E7 tripping

    yea bernard both lives are wired in the same terminal in the programmer. the economy 7 is seperate from the the other immersion circuit. so the only way is to use 2 programmers then? Si
  6. S

    economy 7 horstmann E7 tripping

    got a new twin immersion unvented direct cylinder and customer wants to use economy 7 for heating through the night on the bottom immersion and another circuit for boost as needed on the top immersion. got a horstmann electronic 7 programmer and connected up but it keeps tripping the rcd when...
  7. S

    qualifications regarding working as a self empolyed plumber

    But you need to be "competant" to call yourself a plumber just like you dont need any particular qualification to do electrical work just to be be "competant". I just want to learn as much as i can and i feel like im doing that at college. My first thought was that i wanted to get onto the gas...
  8. S

    qualifications regarding working as a self empolyed plumber

    yes but have not done any work on new heating systems and limited knowledge of direct and indirect hot water, s plan y plan, m plan etc and rules and regs, the technical side which i would never have known if i never went to college. theres much more to the 6129 than pipework. Have to do LCS...
  9. S

    qualifications regarding working as a self empolyed plumber

    I have to cover lead work on the level 2 that im doing this year and electrics. I believe that both are gonna be left out for new students. I want to do the level 3 after this one which will cover more in depth systems including unvented which we are not allowed to cover on the level 2. So i can...
  10. S

    qualifications regarding working as a self empolyed plumber

    I am currently doing my level 2 tech cert 6129 in plumbing at a local college and want to progress onto the NVQ to be fully qualified. Trying to get work with local plumber for the assessment on site side of things but am finding it hard as so many do. Im 42 and have been in the building...
  11. S

    compatability of test leads

    senate only sell the kewtech R2 plug in tester and i only use senate for materials. not even sure if megger do one?
  12. S

    compatability of test leads

    hi i have megger test equipment and wondered if the leads will work with kewtech plug in testers i.e the r2?
  13. S

    ring main

    there is another ring main for upstairs. do you think that maybe the legs have been muddled up?
  14. S

    ring main

    no its about 15 /20 years old
  15. S

    ring main

    the circuit is working. the testers i have are up to the job. i dont know if anyone else has done any work in the property. i have checked most of the sockets except one which is buried behind some computer furniture
  16. S

    ring main

    The problem is that i've got no continuity at the CU with both the L and N conductors
  17. S

    ring main

    how would you know if the lack of continuity was caused by a incorrect wiring of the ring or if there was a break in the cable?
  18. S

    ring main

    is it ever acceptable to just seperate the 2 legs into 2 20 amp radials as an alternative to ripping out cables?
  19. S

    ring main

    Do you mean that you take the L and E of the same leg and join them? And leave the other leg seperated while you test and then the same with the other leg? i.e not cross connected as in a r1 plus r2 test?
  20. S

    ring main

    hi i got a downstairs kitchen ring which has no continuity when testing r1. i have opened up all the sockets to check that they are wired correctly. is there a surefire method to test where a break may be in the cable? eg between 2 sockets?
Back