Search results

  1. P

    weber.set SPF

    Could this be used if i have primed floor with Bal APD?
  2. P

    open fire

    ok, bought some hydraulic lime render
  3. P

    open fire

    Is the wickes one not a lime / cement mortar? if not can you buy it bagged ( ready mixed)? Or could. the area be tiled instead?
  4. P

    open fire

    I want to render the brickwork inside the fire. Could this be done with this http://www.wickes.co.uk/quality-assured-mortar-mix/invt/153706/?source=123_74 Or am i better off with say VITCAS Fireplace Render? The fire will be a basket for logs/coal.
  5. P

    30 x 60 porcelain tiles

    Thanks, I assume Bal APD is acrylic, it says "for anhydrite screed floors" Under floor heating has been on for about a month now and screed down for two months. The Screed is a Lafarge Gyvlon. My aim was to sand all floor areas, vacuum then use APD followed by the Bal PTB Flexible in...
  6. P

    30 x 60 porcelain tiles

    Advice needed for fixing 30 x 60cm porcelain tiles onto a Lafarge Gyvlon screed. ( i assume this is anhydrite screed)? Wanted to know would Bal PTB flexible be best suited or can i use Bal green screed. Underfloor heating is below too. They say " When applying cement-based products such as...
  7. P

    BAL PTB Flexible Adhesive

    joists 400mm centres. floor 18mm wbp ply with tile backer boards screwed down. walls blockwork (new extension) in bathroom and shower to be tiled too. ceramic tiles.
  8. P

    BAL PTB Flexible Adhesive

    would BAL PTB Flexible Adhesive be my best option for a bathroom floor 18mm ply with tile backer boards 6mm . Or could i use single part flexible as this gives me a bit more time working Would this also be required on walls or is a non flex ok?
  9. P

    earth bonding

    hi, yes i,m sure i watched the guy cutting the pipe to divert it
  10. P

    earth bonding

    If i have gas coming into the property (external)in non metal pipe and MDPE pipe for water(external)with plastic pipe internal. What are the requirements for earth bonding in a property?
  11. P

    soil pipes

    indeed, but in black for a soil pipe. can't find them.
  12. P

    soil pipes

    Is there a reason why i,m struggling to find soil pipe y connections from the usual places online?
  13. P

    bath sink waste

    thanks. i thought the pipe sizes were slightly different or is that only push fit and solvent that are different?
  14. P

    bath sink waste

    if i connect my sink waste 32mm to bath waste 40mm, with a 40mm tee and a 32mm reducer . To avoid pressure problems i will fit a HepVO to the bath. would i also need to fit one to sink, or could i use a normal p trap there. Other question is how can i connect solvent weld pipe as the HepVO...
  15. P

    bathroom down lights

    Is IP 44 the ones to get for the bathroom? Not the shower?
  16. P

    bathroom extractor fan

    lol, i know what i meant though, lol so did you :oops:
  17. P

    bathroom extractor fan

    Thanks, ideally ceiling and duct out through suffix, but i can't do this due to building regs and the stupid celotex! looks like a big hole in the wall job for me.
  18. P

    bathroom extractor fan

    Are there any regulations on where an extractor fan can go, i.e height etc? i am using IPX4 fans. i have scaled ceilings and was hoping to place one about 1.5m above floor height.
  19. P

    polythene membrane 500 gauge

    any idea where i can get a clear one, having trouble finding any large rolls? found some at the build centre.
  20. P

    polythene membrane 500 gauge

    Is there a certain type to use over celotex before screeding in underfloor heating, and is it laid up the walls like the dpm sheet? Celotex quote. "A polythene membrane on top of Celotex below a screed or concrete oversite performs three tasks: it acts as a VCL; it prevents migration of the...
Back