Search results

  1. R

    converting door to window ?

    Got a reply from planning today, just for anyone else's reference. "The works you are describing would be lawful provided that they comply with the limitations of  permitted development rights, please see: www.planningportal.gov.uk for more information on these. If your proposal does not meet...
  2. R

    converting door to window ?

    hahaha ^ Very comprehensive responses thank you. Oh i see now this may be classed as works coming under Gov. PD. rights. I guess they will check with the address but i don't think any of the exceptions apply but it gives me some confidence its ok. lpasengland, The house is a semi-detached...
  3. R

    converting door to window ?

    Hi all, Does anyone know if planning perm. would be required to change an exterior side alley door from the old kitchen to a window. So brick half up and then get a new window installed. There will be units installed all along this wall, but it will be more of a utilities area. The kitchen has...
  4. R

    new extension with no lintel ?

    Very much appreciated thank you.
  5. Untitled

    Untitled

  6. R

    new extension with no lintel ?

    Hi, thanks for the reply. Not sure if ive misunderstood you, but its because there will be no wall there Lol. I was hoping to have flush inside walls.. Just continue the wall another 1.4m on the fence side and break into the wall or use a wall starter next to the door. So there would be no walls...
  7. R

    new extension with no lintel ?

    hi, i'm after some advice after a recently built extension. I'm currently filling out the planning form. The bathroom is too small so we wanted to extend it. I have attached 2 pics. I would prefer not to have a cavity wall lintel so the ceiling is flat. So i propose to use a double joist...
  8. Untitled

    Untitled

  9. Untitled

    Untitled

  10. R

    vaillant 831 heat up time

    I was trying to confirm whether what he told me was bs or not tbh. It was one of your own posts agile that I read advising that this should be set and that most installers don't set the maximum output. I did not fiddle with the options prior to the heat up time changing FYI. Sometimes its...
  11. R

    vaillant 831 heat up time

    hey fellas, i've had the latest vaillant 831 installed in march with a salus programmable room stat. The first few days the radiators heated up to 75 degrees in 10 - 12 minutes. But after a few days it seemed to take longer ? the installer says its learning and adjusting :S. pressure is 0.9 bar...
  12. R

    Gas Pipe and Underfloor Heating

    I realise this is 5 yrs on lol. But is there any solid answer to this. I'm putting some of these ideas/interpretations forward to gas safe. Thanks.
  13. R

    covering gas cooker pipe to tile

    bump , does the trunking and weak concrete mix in the channel sound ok then ? The pipe is earthed and will have ventilation on both ends. The pipe in the trunking area has a joint, it is soldiered. What is the main problem here .. The underfloor heating passing electricity onto the gas pipe...
  14. R

    covering gas cooker pipe to tile

    Hi, i emailed gas safe register. The reply is below. I read this in an older thread. Is it strictly a no then ? or is the definition of buried unclear.. 8.16.3 Electrical services Care shall be taken not to damage any electrical conductor when installing pipework. Installation pipes...
  15. R

    covering gas cooker pipe to tile

    Hi Tony, I guess you mean putting it in trunking then filling the channel with the lean mix. I understand that cement can be corrosive to copper. The concrete surface is higher than the trunking. How lean do you think ? a wet sand cement mix.. so it gets underneath the trunking. As long as...
  16. R

    covering gas cooker pipe to tile

    Hi Chris thanks. I've got some pics. Hopefully more info would help.. I could use the plastic square trunking over the pipe(22mm x 3.6m length) and leave one end under the cooker open - 6 inch square area or more if needed - so its just foam. No tiles or metal either. So it would be ventilated...
  17. Untitled

    Untitled

  18. Untitled

    Untitled

  19. R

    covering gas cooker pipe to tile

    Hi, Think i posted in the wrong section before.. my gas cooker line has been moved. The pipe is laid into a concrete channel 8-10cm in width and will have more than 25mm in depth from the finishing level. It has a 10mm thick round foam covering on it. My plan is to fit under floor heating and...
  20. R

    tiling over gas and water channals

    hi, I've had a gas safe engineer in to move a cooker gas line. The pipe is laid into a concrete/screed channel 8-10cm in width and will have more than 25mm in depth from the finishing level. It has a 10mm thick round foam covering on it. My plan is to fit under floor heating and then a self...