  1. S

    DeviMat Issue - Stopped Heating Up

    Looks like we might have a possible solution. I have spoken with the Devi people. Who are now Gaia Climate Solutions Ltd. (formerly DEVI Electroheat Ltd.) and arranged an engineer to visit next week. The engineer will be able to heat the mat up somehow and trace the point at which the...
  2. S

    DeviMat Issue - Stopped Heating Up

    It's been down six months. The warranty is several years 10 I think. But only for the mat. Not the cost of ripping it up and re tiling. :-( Secondary costs as they term it.
  3. S

    DeviMat Issue - Stopped Heating Up

    Hello, We have had a lovely warm floor bathroom for the six months. On Saturday the floor did not heat up. It's a Devimat 3.5 m2 - Timber (350 Watt Capacity) purchased from Tile Fix Direct wired up to a Heatmiser Touchscreen Control PRT-ETS. I have tested the resistance of mat and...
  4. S

    Intergas Combi HRE 36/30 - DHW & Thermostatic Shower Val

    Thanks for the tip. I'll give it a go. It was only two months old mind and I don't think it ever really got properly hot.
  5. S

    Intergas Combi HRE 36/30 - DHW & Thermostatic Shower Val

    All sorted. Looks like it was a duff cartridge. Super hot shower now. Happy man. Regards, Simpic
  6. S

    Intergas Combi HRE 36/30 - DHW & Thermostatic Shower Val

    Ok, So very basic test... results are: - Shower 2.5l = 20 sec Bath 2.5l = 18 sec So near as damn it the same. I'll have to buy a pipe thermostat. Regards, Simpic
  7. S

    Intergas Combi HRE 36/30 - DHW & Thermostatic Shower Val

    Thanks for the reply. Bath temp is super hot as are the rest of the taps. To measure the flow rate at the shower do I just use a bucket? And for the temp at the boiler? Regards, Simpic
  8. S

    Intergas Combi HRE 36/30 - DHW & Thermostatic Shower Val

    Hello, I have an issue with the temperature of the water from the shower. It warm, verging on hot but not quite as hot as I would like it. I will say at this point that it is perfectly usable. It's just that when I come in from a long cycle in the wet and/or cold it's a few degrees under...
  9. S

    Fernox TF1

    Quick question... I think my plumber has installed the TF1 on the wrong pipe! It's currently on the CH Flow. Should it not be on the CH Return? Or does it not matter. Regards, Simpic
  10. S

    Pipe run under under floor heating

    Hi, We are planning on converting the ground floor of the house to UFH when we do an extension. I am also looking at running six pipes from the boiler / motorised valve / UFH manifold area to the garage (part integral) for the future installation of a Heat Store. These pipes will need...
  11. S

    Combi Boiler Two Zone Central Heating With UFH

    The Viessmann Vitodens 200-W with weather compensation and Sub mounting kit with mixer looks like a rather expensive option. The boiler is £400 more than an Intergas one and then the Sub-mounting kit is ~£550 and WC unit another £150. nearly £2000 on kit before installation. What benefits...
  12. S

    Hi, what software did you use for your schematics? Also did you end up using a Viessmann boiler?

    Hi, what software did you use for your schematics? Also did you end up using a Viessmann boiler?
  13. S

    Combi Boiler Two Zone Central Heating With UFH

    I'll have a look at that boiler. As a side question.... does anyone know where I can get some software to draw heat schematics properly?
  14. S

    Combi Boiler Two Zone Central Heating With UFH

    Hi, I'm looking for some help to verify the proposed schematic I have attached. The context is replacing an open vented system in a 60's / 70's house with a combi and UFH. Looking at a Intergas Combi. Also, if someone could point out how to add a zone for a towel radiator as well...
  15. Untitled

    Untitled

  16. Stuff

    Stuff