Search results

  1. H

    LG DVX582H DVD player with USB

    I have just got this new DVD player and I am perfectly happy with it. My question is should my ipod (80gb model) work in the usb port of the LG DVX582H?? Or is an IPOD Mp4 or some other format. Can I do a cheat to enable it maybe?? :? It does say in manual 'music storage device' can...
  2. H

    BEKO WM6251W FAULT

    Success!! :D The brushes did the trick. £25 well spent and they came with new housings so I had to literally screw them back on and connect. Working like new with the flushing out that I did as well. So the best tip we can all give is 'check the brushes' when it stops mid cycle...
  3. H

    BEKO WM6251W FAULT

    Hi Leccy, Reset process didnt work, but me dad said 'check the brushes' , so I had a rethink and she did say it stopped mid cycle. So checked the brushes and Eureka, one side was flush, loads of carbon on commutator, so took em off and gave the comutator a brush up as well...
  4. H

    Upstairs rads hot d/stairs cold

    Thanks for the reply, Yes there are 2 tanks in loft, I checked water level in CH header tank and it was below half but the ballcock was at its final position. I manually pushed the ballcock down to fill the tank till it went down the overflow but this made no odds. So is this a vented...
  5. H

    BEKO WM6251W FAULT

    Thanks but this model does not have actual fualt codes. :? I will try the reset process and report back. :wink:
  6. H

    BEKO WM6251W FAULT

    Hi, all my m/in/laws BEKO WM6251W washing machine has gone on the blink. The symptons: Cannot select a programme or cancel what it appears to be stuck on - SPIN - but doesnt spin - Drum sensor??? Will not cancel or restart The start and spin/end lights are on It will drain I have...
  7. H

    Upstairs rads hot d/stairs cold

    Hi all, I have 2 problems that may or may not be linked?? My sisters heating has just decided to only heat u/stairs rads and HW has never worked from controller and stops CH igniting. :? Symptoms: Rads have heat u/stairs but cold d/stairs. The rads are on are not very hot The...
  8. H

    Not enough hot water,only 1/2 a bath and heating is average

    Cheers Spraggo, 1st two lockshields I have looked at are about 1+1/2 turns only so I guess they are all the same! Not doing them till tmoz, got all day to do it then. So the key here seems to be to let the boiler,TRV's & stats do their job, heating on permanently so house reamins at...
  9. H

    Not enough hot water,only 1/2 a bath and heating is average

    I meant lockshields not lockheads. Apolgies chaps.....Doooh :oops:
  10. H

    Not enough hot water,only 1/2 a bath and heating is average

    Confused.com or what! :? My scenario now is: Heating is on, rads up to temp. We have 9 rads and 3 towel rads with no TRV's. The dining room TRV is off due to guinea pigs in there. 1.Is this going to cause a flow problem/unbalance/unefficient running of system with TRV off?? 2.The...
  11. H

    ROK down the pan - Need work JIB App Elec, CSCS,IPAF & P

    Hi All, From the demise of yet another major contractor, ROK, :evil: to whom I was a s/contractor but luckily through an agency. I am loooking for work in the East midlands area or Nationwide if lodge expenses etc are inc. Got mouths to feed and Xmas is coming, it will be wood...
  12. H

    PME, is it free to have it installed??

    Morning all, Is it free to have a PME done on an exisitng domestic property which is 40 years old.It is in Nottinghamshire so it would be Eon I presume Thanks Andy
  13. H

    2.5kw elec oven wth gas hob. New circuit or local socket??

    Morning all, Mum and Dad are having their kitchen redone and the owd girl wants a new cooker which going to be electric with seperate gas hob. Currently there is no cooker cct in kitchen just a 16A radial serving 3 twin sockets above work surface and 1 single low level adjacent exisitng...
  14. H

    Not enough hot water,only 1/2 a bath and heating is average

    Morning all, Vast improvement on the heating from cranking up boiler temp dial and tank stat to 60. I assume I am using more gas by doing this??? Not checked expansion/header tank yet and float/ballcock movement Also when bleeding rads should the system be on/hot or off/cold or warm...
  15. H

    Not enough hot water,only 1/2 a bath and heating is average

    Ok , so lets just get this right. Tank stat @ 60 Boiler dial @ 80%, there are no numbers on dial in bottom r/h/corner above indicators. So turn c/wise 80% TRV's set on 4 And check expansion/header tank for free float/ballcock movement. Should be full 3/4 Check. Simples...
  16. H

    Not enough hot water,only 1/2 a bath and heating is average

    The water runs cold not stops running. I have just read cylinder info and that even says 1 bath/shower for 85 model and recommends a 125ltr for 2 baths showers which we have. Me thinks somene has cut corners and made some dollar! T****r. If I turn stat upto 60 wont that make taps...
  17. H

    Not enough hot water,only 1/2 a bath and heating is average

    Hi Picasso/Spraggo, thanks for the replies. Ok the tank stat is at 50, turned it down today as Mrs was moaning about how hot the water is coming out of the taps. We have found that if we turn it down at the boiler it also turns the heating down/rad temperature? Make sense are is that a...
  18. H

    Not enough hot water,only 1/2 a bath and heating is average

    Can anyone advise on low hot water capacity and average heating before I bring the plumber back who did this complete new system 2 years ago on my property. Here is the spec of the system: Baxi Solo 24 HE condensing boiler Centercyl HE85 hot water cylinder with Backer BT15 rod stat Wilo...
Back