    Heatslave 20/25 lockout advice appreciated

    Sounds like an air lock in the fuel line. What model burner is fitted to the boiler? When you changed the oil pump, did you set the pressure with a gauge? If not, then go back to basics and make sure there is pressure. Where and when are you measuring the voltage to the solenoid? If at the plug...
  2. O

    Replacement for Danfoss 3060 timer?

    The options you need to establish are Y plan, S plan Cplan or GRAVITY HW. I think you may be confusing gravity with an open system. The pointer a lot of the time is how many flow and return connections your boiler has. Pumped systems will have one of each, whilst gravity hot water will have 2 of...
  3. O

    Aga ranges

    So we still don't know what is your problem. Is this a bespoke oil Aga or a converted one? I had lots of customers who always 'serviced' their own appliances but was called in to 'service' it when their efforts failed. The biggest problems with self service occurred with blocked filters, air...
  4. O

    Oily smell from Worcester Bosch Greenstar Heatslave 2 25/32

    Looking back at your posts, I would start again at the point where the supply pipe enters the room. There may be a joint external to the boiler that is weeping, or even an unprotected pipe that has been eroded by mortar.
  5. O

    How much does control methods change the fuel used in central heating?

    It has only gone over the top for people who have too much time (and money) on their hands.
  6. O

    Pressure reducing valve

    What problems do you have? Do you have anything that is pressure sensitive? Some oil combi's were stated to only have 3 bar cold inlet and happily blew seals if overpressured. If you have nothing to protect, then I would not bother.
  7. O

    Tap re-seater tool thread type

    I would have thought the 1/2" would screw into that tap. I doubt if it is anywhere near the age of the house. Having said that, I don't know what you paid for the kit, but it would have gone a long way towards a new tap. It looks like someone's had a right fit with that one.
  8. O

    TRV and wall thermostat in the same room, how can it work any other way?

    It all depends on the relative settings of the thermostats. Presumably the wall stat is a full system thermostat and controls the whole system whereas the TRV are specific to one room. Surely the normal set up would have a full system control in a relatively open area, with localised control for...
  9. O

    Thermostat behaving abnormally

    Your pictures of a kitchen tap and cold water pipe do not match your titles
  10. O

    Danesmoore 20/25 driving me mad

    No spark is indicative of either photocell fault, faulty transformer or control box. When the spark fails, after checking the electrode connections and leads, disconnect the transformer lead and check for voltage at the plug. If there is no power then you've probably found the fault. To...
  11. O

    Danesmoore 20/25 driving me mad

    What burner are we talking about, and is it down firing from the top or horizontal from the front?
  12. O

    Oily smell from Worcester Bosch Greenstar Heatslave 2 25/32

    Is this a boiler with a down firing burner?
  13. O

    Filling Loops open or closed?

    The flat sides need to be at 90 degrees to the pipe to be closed. You may find there is no positive stop to the valve if it is a ball that is operated. What do you have at the other end of the filling loop? If that is closed, then it will also stop the flow.
  14. O

    Replacement Greenstar Danesmoor boiler - advice please

    Later boilers 'just out of warranty' of any make do not last as long as their predecessors. The replacement of parts such as photocells or pump coils is a fact of life with any boiler. Whilst the modern control box may give signals indicating faults to be told 'no flame detected' is not...
  15. O

    Old Worcester Heatslave 15/19 (Red light) Not working

    Is it the red light on the control box? Have you tried pushing it? That is a very old burner and if the control box has failed, whilst it is possible to replace with a newer box, you may be halfway to the cost of a complete new burner.
  16. O

    worcester heatslave 15/19 - How to Bleed Advice

    Don't forget you may have in line filters fitted that will also need bleeding. Follow the oil line from the tank all the way to the burner to check for other bleed needs.
  17. O

    Oil boiler not firing any ideas?

    Have you pressed the reset button on the control box on the burner?
  18. O

    Riello pump pressure test

    What model burner do you have? The pressure port usually used is the conveniently placed lower hexagon screw below the pressure adjuster. What problems do you actually have?
  19. O

    Riello pump pressure test

    With the greatest respect, asking a question such as this does suggest you should not be messing with your burner.
  20. O

    Heatslave 20/25 diverter valve problem.

    Consult the manufacturer's instruction easily available on line. This valve differs from many.