  1. U

    scantronic i-on160ex + isd02 - line fail

    Thanks Sparky - is that 2 = a and 5 = b?
  2. U

    scantronic i-on160ex + isd02 - line fail

    Good morning, I've setup an i-on160ex with the speak dialer, isd02. The dialer doesn't seem to be able to see the telephone line - though the connections are made to the master socket (Socket was just installed last week if it makes any difference and is 5c marked by bt). Tests so far: on the...
  3. U

    two battries on Galaxy Dimensions 96?

    Morning all, The manual says i can connect two batteries - but i can only see connections on the panel for one. Is it only on certain boards or do i need to wire them in parallel?
  4. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    Sorry ment selfmon vkp, clearing it worked!
  5. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    if i understand right, the default manager pin is 12345? (master manager), the pin i have set for that user works from the keypad but when i put it in selfmon remote - for the RSS Password, it says Login Failed.
  6. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    Hardwired is fine, selfmon connects and tells me invalid pin, so need to read up on what I seed to do there!
  7. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    Sorted that issue... Not sure on the wiring colours, manual shows a yellow on back page, in the end I just used a piece of cat5, a to a, b to b and + to +, - to -. Went into and out of engineering and found new module, pinged from laptop and found something at the end.
  8. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    Hi galaxy guy, Unfortunately no joy! Setup is in images below... IP is set to 192.168.1.251 Gateway is 192.168.1.254 Subnet is 255.255.255.0 Can't see it appear on my router as connected devices but the cat5 cable is working fine for my laptop I have two touch centers and one Mk7 , so 3...
  9. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    thanks for the response, So far looks like everything is working on the individual zones, using mk7 and touch center, wiring wise and config is working on all keypads, i can set and unset on them, and i guess worse case for now its all set or nothing, I was hoping to use the opengalaxy program...
  10. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    Some progress today, managed to name and set my zones up (i think!) bit of confusion re the entry/exit zones. Need some help with groups if anyone has experience. The touch center says group a has a fault, but not what the fault is... and also is there anything to note when setting up groups...
  11. U

    Honeywell galaxy dimensions 96 - easy mapping for config?

    Hi all, I've just installed and powered up a Honeywell galaxy dimensions 96 panel, with two touch centers and a Mk7 keypad. The programming menu seems a bit of a mess in the manual, certainly not as easy to understand and follow compared to my previous experience with scantronic 9751/2 and...
  12. U

    Honeywell viper wiring

    Interesting, so i can set the two without contacts as 24 hour monitored, but the one with a door contact has to be armed/disarmed as part of the door zone? As such, if the zone is disarmed, someone could set it off and the alarm wont activate?
  13. U

    Honeywell viper wiring

    I have three honeywell vipers - two are just vibration, third is with door contact. All three will be wired to their own zones - so i dont care too much re first to alarm, and two of the three will be hidden behind a panel, so dont really need the led either. I'm using a galaxy dimensions 96...
  14. U

    Non-Maintained emergency light kit

    Hey, that's the problem I had, and reading back, you are looking to put it exactly where I have, bottom of the stairs/ close to front door... Ie light the way out. As I said in my earlier post, it's costly, but seems to do what I need, without having to have a different light fitting. It's a...
  15. U

    Non-Maintained emergency light kit

    Hello, so far I've had no issues (but no long unplanned power outages either!) I tested mine for a duration, after initial charge while doing some tidying work (testing and marking old consumer unit circuits), well over an hour and light was on with no noticeable dimming. I'm aiming to get a...
  16. U

    Rad getting hot with hotwater

    Sorry ment normal thermostat (ufh) and a second opentherm stat for 1st floor
  17. U

    External Insulation DIY - questions

    Soil stack, got cast iron too, and it's in the wrong place, so I'm thinking of replacing all the way from man hole (the new location is only a meter or two from where manhole is do easier to start fresh then mess about with the existing. I'm aiming to take the Sofit boards off and push the...
  18. U

    Rad getting hot with hotwater

    Got this sorted eventually, ufh now goes via tank, actuators on manifold don't heat up floor unless they are open, do no heating when water is on. Also got wiring swapped so hot water is wired seperatly, as hot water priority... Well sort of! My dial channel programmer doesn't allow for a...
  19. U

    External Insulation DIY - questions

    Thanks for the replies, due to amount of work I feet I'll end up giving this out to someone, need to re pipe soil and rain water pipes from chamber to roof, insulate, create window boxes for round bays, and screed. Not happening fast with a 9-5 job on top :( Any thoughts on the single layer Vs...
  20. U

    External Insulation DIY - questions

    Tomfe, that's basically what I was thinking in terms of fixing the windows. (Though not sure how I can do the round bay and keep it strong!) Do you have pics of the internal setup of those? Or drawing of the cross section?