  1. C

    Texecom Errors

    This is what Wintex shows me on diags
  2. C

    Texecom Errors

    I have A keypad downstairs which has a door contact on zone 1, and a keypad upstairs which has the stairs PIR wired into zone 1. have set this via Wintex - As in RKP zone 1 mapped to zone 2 on panel etc. Havent used resistors anywhere...
  3. C

    Texecom Errors

    Ive check ed keypads and they are different on the Dip Switches, The RKP's are wired plus and minus black and red and T & R Blue and Yellow leaving me with 2 White and Green but I don't have these connected at either ends... Are they supposed to be ? keypads are working ? All 4 wires connected...
  4. C

    Texecom Errors

    I need help wiring the RKP tamper, Do I wire that also into the T & R terminals on the panel then link it into T & R in the keypads ? Thanks
  5. C

    Texecom Errors

    Excuse the cabling I hadnt terminated it all at that point it was all just in place for reference.
  6. C

    Texecom Errors

    nope only have 2 keypads both on network one. PIR on stairs is a Texecom Quad
  7. C

    Texecom Errors

    Hi have discovered a few errors today after firing up my alarm, RKP 1,3 Tamper and Faulty Detector (stairs). Also I keep getting the message on screen "Engineer working on site". I can reset and then I get my banner screen but cant arm/part arm. Any ideas ? Thanks in advance all.
  8. C

    Arming back gate

    Hi all, question for you... id like some advice on best practice / or any advice. I want to arm my back gate (door contacts), however its a good 40 - 50 meters away from the back of my house, then another 15 meters or so to my alarm panel... what would be the best way ? My idea was to run 4...
  9. C

    Texecom RKP - Door Contact

    That's fine I was just making sure!! Thanks!
  10. C

    Texecom RKP - Door Contact

    OK my next question is Ive run 4 wires to the Door Contact, Red/Black , Blue/Yellow... Blue Yellow is tamper twisted... Red and Black connecting to the contact screws, but where exactly on the keypad zone do I wire them up ? I can see zone 1 and 4 terminals, I'm guessing 'A' will be my Red/Black...
  11. C

    Texecom RKP - Door Contact

    Good Afternoon This is probably dead simple but I'm putting in a door contact (Reed witch) on my front entrance. I have 4 core cable from it to my RKP. I can see how to wire up the door contact side... however where abouts do I connect the Door Contact inside the RKP is it on Area 1 /2 ? (Im...
  12. C

    Fuse Box

    Surely something that old wont just be costly to get replacement parts for but may also be a fire risk ?
  13. C

    Texecom Exodus - Smoke/Fire Detectors

    Im going to see if I can get hold of one of the exodus;s and see how it goes!! Thanks for your testing @secureiam
  14. C

    Fuse Box

    If it is A 2016 preview..... its a 2016 BC!
  15. C

    Fuse Box

    That CU looks like its 30 days older than God! May want replacing anyway ?
  16. C

    Texecom Exodus - Smoke/Fire Detectors

    OK I presumed to be honest the exodus had an internal sounder ?
  17. C

    Texecom Exodus - Smoke/Fire Detectors

    Thanks for your reply I will definitely consider your advice! Never touched these before so will be interesting if I go down this route!
  18. C

    Texecom Exodus - Smoke/Fire Detectors

    Hi all, Looking at getting the above and installing it... Never done anything like that before regarding this product. How is it setup ? is it wired to a zone on the panel ? how is it setup ? is it always armed/set ? Any information greatly appreciated! Thanks
  19. C

    Texecom Elite 48

    Ahh I see, the way I was going to do it is run the cable direct to one of my servers which I have connection to anyway and run a virtual machine with Wintex on. Then I can remote into the Virtual Machine whenever needed to run Wintex. Can do it from my armchair then :) However the alerts...
  20. C

    Texecom Elite 48

    Looks like it'll do the same job ?