  1. S

    Lightsys & ELMDENE INT500

    Thanks for the reply.. Had 5mins tonight so just tried connecting it up, went with the following: Bell+ to H+ COM to H- LS to M- it still didnt work, but I do think the current sounder might be broken. I will give it a try once the new one arrives.. One thing I...
  2. S

    Lightsys & ELMDENE INT500

    Thanks for the reply. It was installed by a local engineer, but he did admit a few times he was not used to the system. Spent a lot of time on the phone during its install. I have ordered a replacement sounder, as assume this one might now be damaged. In the manual it says “Ls” can be set to...
  3. S

    Lightsys & ELMDENE INT500

    Hi, Over the weekend we noticed the alarm didn't seem to be working. Turned out its working fine, but the internal sounder, (a Elmdene INT500) is not working.. If we arm the system it used to emit a squark, same on disarming.. Not it just emits a very small clicking noise.. I removed the...
  4. S

    Is there a better way? - 2 or 4 Channel Light controller

    Anyone know a better way to do this.. I have the following set up in my kitchen either side of the hob and extractor: Left: 1 x Cupboard Spot (12V DC LED, 2W), and 1 x Cupboard Strip (12V DC LED 15W) Right: 1 x Cupboard Spot (12V DC LED, 2W), and 1 x Cupboard Strip (12V DC LED 15W) On both...
  5. S

    SMS from Risco Lightsys Alarm

    Hi, There is a GSM activity light on the board.. The main conclusion was taken from if I disarm the alarm within 10 seconds, I never got a SMS... More than 10 seconds, there was always an SMS sent
  6. S

    SMS from Risco Lightsys Alarm

    Ok well, a bit more on this.. I do get the SMS from the alarm, but seem need to be active for a while before it sends the message. This makes sense, it would be annoying for a message to be sent if your just a bit slow at entering the code.. Does anyone know how long it needs to be active for...
  7. S

    SMS from Risco Lightsys Alarm

    no, but that's just to avoid annoying the neighbors. I have a day off planned and will do some testing. Unless there is a way to stop the bell during testing but appears not to be
  8. S

    SMS from Risco Lightsys Alarm

    Have messaged him.. hope he might reply..:) It's odd, works fine for arm, disarm, setting, unsetting etc... Just nothing for when the alarms is triggered.
  9. S

    SMS from Risco Lightsys Alarm

    yeah.. I know risco play things close to their chest. But thought someone might be able to top help. Options 5 4 2 1 and 5 4 2 2 seem to be the same things... The wording is the same.
  10. S

    SMS from Risco Lightsys Alarm

    hi, I have a Lightsys alarm fitted and all works well. Recently I fitted the GSM module to the alarm.. I defined 2 FM numbers, and the event on which I which i want to be notified.. All worked well: I could set, unset, and check the status via SMS On ARM I would get a message. (just for...
  11. S

    Decorative water channel

    Thanks for the replies.. think the guttering might be an option..
  12. S

    Decorative water channel

    Hi Guys, In a few weeks we are about to start on the garden, we are looking to install something similar to the link below: https://s-media-cache-ak0.pinimg.com/originals/35/af/1b/35af1b083a44d7f017f992570c037733.jpg It will run across a section of the lawn, and will be about 4m in length...
  13. S

    Underfloor heating mat and bathroom isolation

    Thanks for the reply.. this is the same unit, but not my picture here
  14. S

    Underfloor heating mat and bathroom isolation

    Thanks for the reply... Your correct there is no RCD in the CU.. Good point about the 5amp fuse.. The change to the CU is just belt and braces, prevents someone adding more load later. I know it notifiable, but lots must be installed without being checked.:)
  15. S

    Underfloor heating mat and bathroom isolation

    Hi guys, Having some work done in the bathroom. When finished the installer will have fitted a small heating mat under the new bathroom floor (<300W). I have a few questions about connecting it up. Previously the bathroom had a 6mm cable running from a wylex fuse box (with MCB type fuses), to...
  16. S

    Lightsys connections to Novagard 6

    So best not to use the internal bell? Or Can Power be drawn from else where? The Dc feed next too the mains jack?
  17. S

    Lightsys connections to Novagard 6

    if both have internal batteries could I run both as SAB? (or am i getting these confused?) The INT500S when sounding pulls 220mA The NovaGuard has a max of 464mA The sensors have Quiescent current consumption of 5x 11mA (55mA) Keypad 52mA So 791mA, call it 800mA The Lightsys can supply...
  18. S

    Lightsys connections to Novagard 6

    Thanks for the reply.. Do I not need to worry about the set+ for a confirmation of setting the alarm? The int500s manual says: "The INT500S is classified as an internal self powered sounder and has an on-board battery which is recharged via the external power source. This battery is used to...
  19. S

    Lightsys connections to Novagard 6

    Hi all, After some help with the connections from a lightsys to a Novaguad bell.. I assume that the lightsys is not a NovActive compatible system? And that I will need to make the connections via standard wiring.. I set the DIP switches to set the box up as a SCB. I made the connections as...