Search results

  1. K

    Kitchen cabinet hinge off, whats the best way to repair ?

    The kitchen cabinet door is off. The wood is out of the threads as they left it until i came out. Whats the sturdiest way to repair?
  2. K

    Can I fit a tap reviver kit to these taps?

    Thanks @picasso. That did it. It got the taps tops off. The kit that fitted was the 1/2" kit as you suggested. What a job I had figuring out the spacers to get the tap to close. Brass spacer fitted to tap was to short; tap wouldn't close. Extension brass piece included was too long; couldn't fit...
  3. K

    Can I fit a tap reviver kit to these taps?

    Taps in photo were fitted a long time ago, how long before 2007 I don't know. Hot tap hardly turns and is tight. So I got a tap reviver kit from Screwfix, see photo. However I can't pop the cap on top of the tap to release the screw. I drilled down a bit, see photo, and top of tap still not...
  4. K

    cap off 3/4 inch bath taps

    Bath has two 3/4 taps, hot and cold. Was considering replacing knackered swirl taps with reviver kit. Bath is never used and capping taps off avoids possibility of young student tenants flooding over run bath onto neighbours underneath. Anyone know if there is an equivalent to a reviver kit that...
  5. K

    H-section shower rail has never run smooth across join

    It was fitted carefully last year. It never ran smoothly then. I tried a bit of force for re-aligning at time of fitting. Will try sanding edges more and may be twisting for re-alignment again. Twisting did not seem to help last time. The mix of the plastic track 'joiner' and the aluminium rail...
  6. K

    Kitchen counter top join swollen with water ingress

    It's not going to be replaced. Ideas for sealing?
  7. K

    UPVC window sill that is not UPVC window sill; damaged, how to repair

    Just discovered having taken an end cap off that it is plastic underneath the white veneer. It is a thin white veneer on top and a brown plastic structure underneath. Here is the end section.
  8. K

    H-section shower rail has never run smooth across join

    I have an H-section shower rail. The shower curtain has never run smoothly across the joins. It sticks. Any obvious ideas for simple adjustments/ mods, or quality replacement that works. Thanks
  9. K

    Kitchen counter top join swollen with water ingress

    Hi I have a join in a kitchen counter top that has become swollen with water ingress. It's beside the sink. See photos. Ideas for sealing it up without replacement. One surface now rises 6mm above the other Thanks
  10. K

    UPVC window sill that is not UPVC window sill; damaged, how to repair

    On another sill cigarette burns like this. What to do without replacing the sill? Only thing I found so far is this. Plast-Aid Seems like might be a bit of a gimmick. Anyone any experience with it? Thanks
  11. K

    UPVC window sill that is not UPVC window sill; damaged, how to repair

    MisterG, I don't know who fitted it
  12. K

    UPVC window sill that is not UPVC window sill; damaged, how to repair

    Hi, I have a window sill damaged by an incense stick someone left on it. You can see if you look at the photos that the internal sill is not Upvc because it has burnt through the this plastic(?) veneer to the wood composite below. Any ideas how to repair? Thanks Is there a paint type that...
  13. K

    Best way to access roofline for painting or replacing or over cladding fascias

    Going to go for 2 x tressles and 3 x scaffold boards from HSS hire. Cost is approx £22/week Thanks everyone
  14. K

    Best way to access roofline for painting or replacing or over cladding fascias

    Bungalow needs fascias painted and or part replaced / overclad. Plastic gutter will have to come off to do this. House is quite large, fascia perimeter is 64m. Fascia is at height 2.7m above ground. If I put a ladder against gutter then stability is spongy as it springs off the plastic gutter...
  15. K

    Need a radiator pipe "kick plate"

    Have 8mm OD (outside diameter) copper running between radiator and floor. It's getting kicked and worried it's going to come apart. Does a steel protector "kick plate" as outlined in drawing exist, or something similar. Not worried that it looks ugly. (Changing the pipework to more robust 15mm...
  16. K

    MK Logic plus socket terminal screws, where to get?

    I am looking for terminal screws for MK logic plus double switched wall sockets. Had a fairly extensive look online and cannot find them. Have even phoned MK and they say they are not available. They are a screw; of course they are available. Screw measures approx m4.5 and is 9mm long. Anyone...
  17. K

    Fitting FD30 fire doors

    Hi, thanks for the explanations; I saw what pads are at link here but I cannot see that this forms a smoke seal in the hinge region What is the "1 blade"? Are smoke seals ignored in the region of the hinge? Why are these pads placed under the hinge?
  18. K

    Fitting FD30 fire doors

    Can the intumescent brush seal go on the door. I reckon it will be easier to router down the middle of the 3 door edges that pull the door casing out to do the same. What about the 3 special hinges, does there have to be seal around the edge of the hinge, or can it be ignored.
  19. K

    Fitting FD30 fire doors

    I have to fit 5 x FD30 fire doors (4 bedrooms and a kitchen). Fire officer has requested brush type intumescent seals. How does intumescent seal work regards going across hinges, if that's necessary. Two or three hinges. Can anyone advise method.
Back