  1. K

    Air con split unit/inverter

    What would be the rough running cost for say 12000 btu split unit in heating mode ?, any ideas ?
  2. K

    Reducing 10mm to 8mm

    these will do it, make sure the pipe is round, file any burrs off when you cut it. http://cgi.ebay.co.uk/JOHN-GUEST-10MM-8MM-water-pipe-REDUCER-speed-fit_W0QQitemZ230117384856QQihZ013QQcategoryZ20684QQtcZphotoQQcmdZViewItemQQ_trksidZp1742.m153.l1262
  3. K

    Reducing 10mm to 8mm

    If its copper tube then this will do it, http://www.buyplumbing.co.uk/VEM-SRR1008
  4. K

    Glowworm back boiler, Inset BBU 40 or 50.

    When we used to do council house refurbs using Rolyat or Elson tanks with gravity primaries a Drayton Cyltrol valve was always specified, http://www.uk-plumbing.com/acl-drayton-invensys-cyltrol-valve-1bsp-angle-p-1377.html These are set to stop overheat of the domestic hot water due to...
  5. K

    Is there anything wrong with this work - with pics

    Its not the best job in the world but I have seen a lot worse, one thing to mention though, is that if the pan connector in your pic is any indication of the finished position of the wc pan, then you want to be careful when you screw the pan down, ie that your screws dont hit those pipes.
  6. K

    plastic wall panels

    Hi not tiling strictly but a question about plastic wall pannels from B&Q,I have used these to line my shower-room,including inside the shower enclosure,I now have leaks down behind the tray.I followed the fitting instructions and put a bead of silicone down every t&g joint,the tray is sealed...
  7. K

    Vaillant ecomax 824 2e

    Thanks lads ,I will check all of theses things.When I turned the boiler off at the facia the temp was only showing around 55 degrees so I dont think it was lack of pump over-run though,and this is I believe one of the earlier models as it has the system pressure sensor near top-left in the...
  8. K

    Vaillant ecomax 824 2e

    Thanks for that Tony,I will take both ntc's as well (its a 2 hour drive into mid Wales) and change those as well if you think they have been cooked by being run with low system pressure,but why would the the boiler go to f20 by being turned off and on at the fascia control ?,what other test...
  9. K

    Vaillant ecomax 824 2e

    I had a problem this morning with this boiler,when I arrived on site it was showing fault code f20 which is overheat.I checked the fault list in the menu and this has not happened before.The boiler lit after resetting it and ran ok,I checked the meter readings off the flow and return thermistors...
  10. K

    suzuki ignis cv joint

    thanks for that.
  11. K

    suzuki ignis cv joint

    Hi,my wifes 2002 Suzuki Ignis has develpoped a clunking/clicking from the front near side wheel when turning corners,I suspect the cv joint,not within my experience to do it myself so I was wondering if anyone knows what would a fair price be for a garage to charge,thanks.
  12. K

    Mikrofill Ethos 65-120 manual ?

    Anyone got the manual for this boiler in pdf to mail to me?,thanks,Kevin.
  13. K

    ideal mexico he24

    Yes lads that is exactly it,thanks for that,the end of the flue pipe has been cut at 45 degrees,it has no grill on the end as a standard fan flue would to stop entry of birds etc, so that will have to be sorted.
  14. K

    ideal mexico he24

    Came across an unusual flue arrangement today,it was fitted in a building I was visiting to change some trv's.It is a mexico he24,the flue comes out of the building into an alleyway with the boiler being situated where the flue would blow down the alleyway length-ways if it was a standard type...
  15. K

    suzuki ignis rear brakes

    Hi,I am going to change the rear brake shoes on my Suzuki Ignis,has anyone done this car before?,anything I should look out for or be aware of ?,thanks.
  16. K

    New ventilation regs ?

    Someone mentioned to me today that there are new regs coming into force this year regarding ventilation,anyone know any more about this? or is it something we, (corgi registered) have known about for a while,ie open flued boilers etc.Nearly all my work is commercial,so a lot of the boilers are...
  17. K

    Delonghi microwave

    Thanks folks,the user manual is a joke,it says,in the troubleshooting section, "if the light has stopped working,it is probably due to the bulb having burnt out",not a hint as to how to change it or where it is.Had a look on the internet and it seems that this model is exclusive to Argos,that is...
  18. K

    Delonghi microwave

    Hi,I have a Delonghi ac930amq microwave,it is working fine aprt from the light inside the oven went off today,does anyone know where the lamp is located as I cant see anything resembling a lamp and not having taken much notice of it before I cant remember where the light source was when it was...
  19. K

    BAXI BERMUDA 551 BACK BOILER PROBLEM

    Cast iron heat exchanger is probably sooted up due to blocked lint arrestors,get someone corgi reg to check it out and service the boiler asap.
  20. K

    Cutting cast iron soil pipe.

    The cast cutter you showed from hss is the way to go,not easy to use till you are used to it,you will need at least an inch clearance around the pipe for the chain cutter to wrap around.You wrap the chain around,each link has lugs that drop into recievers,then you ratchet with the long handle...