    Immersion cut-out with a twist

    Earth continuity been checked? As suggested, an experienced electrician should be able to fault find. How is the immersion powered? Does it have it's own radial circuit from the CU or is it a spur from the Ring?
  2. Madrab

    Changing mixer shower and tap

    You want to take the controls and the plate off of the shower to see what's behind, depending on what access there is will determine what needs to be done. As suggested - tap off the basin is straightforward.
  3. Madrab

    Re sealing a bath

    Just need to ensure the new will take to the old - use a solvent cleaner - IPA - Meths - White spirit etc before applying.
  4. Madrab

    Re sealing a bath

    Are you talking about the silicone that runs in the corner vertically up the tiles? Sometimes best to cut the first 500mm and renew so the transition is all the same new silicone. Would really comes down to condition but TBH for all it is, it would be just as easy to do it all in a oner.
  5. Madrab

    play / tolerance in 110mm waste fittings - tweak gradient possible?

    As long as it stays within the min fall requirements - 18mm/m fall then it would be fine. Though if I gauge it correctly 1:60 is slightly below that? Worth noting though that 18mm is the min per the regs and not necessarily the best when it comes to a pipe run being free draining and self...
  6. Madrab

    How to best relocate this waste pipe?

    Is it a push fit coupler that's on the pipe with the blanking plug in it?
  7. Madrab

    Unvented cylinder - documentation

    nothing new there, usually the same with the boilers and if they were fortunate to be registered then the warranty usually falls off in only 2yrs.
  8. Madrab

    Tundish and trap

    PRV's in that instance usually let go at a certain pressure as they are there to protect against excess expansion and they are usually located on the cold feed downstream of the heater, so super hot water isn't normally an issue - TPRV's are the ones that let go at specific high temps and...
  9. Madrab

    Unvented cylinder - documentation

    OK - that garbage but I can understand their position, as the installer didn't follow a simple process. Would they not even consider getting one of their engineers out to service the cylinder and then (re) instate the warranty, then pass on the cost to the installer? If not then I'd pass that...
  10. Madrab

    CrossWater Basin Mixer type tap that has no visible allen/hex screw in it when nut is removed.

    +1, pic 3, that's an allan key grub screw in there for sure!
  11. Madrab

    Unvented cylinder - documentation

    Strictly speaking it should be the chap who installed it is the one to sign but TBH as long as you have a correct certificate now then that's all you want. Now it's time to ensure that the warranty is in place. :ROFLMAO:
  12. Madrab

    Stopcock weeping

    Time to replace the stop tap for a new 1/4 lever valve. it's done it's job and is worn now. PTFE tape is a great stop gap and it will work for a bit but it doesn't stand up for long and the gland will just start to leak again when used in the future. Find the outside toby, shut it down and...
  13. Madrab

    Shower inlet valves need rotating - how to seal?

    Alternatively, use gas PTFE tape, normally 7 wraps. Take the fitting with nothing on the threads and see how far it screws on before reaching the end of the thread. Mark the threads with a pen. Wrapping the male end and using the mark as a guide screw the fitting on until nearly there but the...
  14. Madrab

    How to best relocate this waste pipe?

    How wide is the unit space? Is it tight to 600mm? If there was extra width space then the waste could be run to the left then upwards to create a stand pipe. Normally a full sized freestanding D/W is ~ 600mm deep, so even with it tight to the wall, without any pipes it will be extending 60mm...
  15. Madrab

    Tundish and trap

    Wouldn't see why not, as long as it certified to take the temps that may be released under fault conditions. It does state that it is designed to be used with, amongst other things, water heaters and PRV valves
  16. Madrab

    WB Boiler 1.A lower setting query/ post adding insulation

    Ah ok, that's the CDI Conventional (regular boiler) which was in essence the precursor to the CDI Classic range. These boilers, even the later CDI Classics, were never really shipped with a menu per sé or designed to be range rated, though as suggested they do modulate. That being said if...
  17. Madrab

    WB Boiler 1.A lower setting query/ post adding insulation

    What is the GC number off the sticker on the front, as I was under the impression that the old CDI regulars couldn't be range rated.
  18. Madrab

    ICOS24 condensate trap plastic nut corroded

    +1, that's not really corrosion. The large number of heat cycles and the amount of time that it has been in service, then the plastic has slowly broken down. It is rare but I have seen it a couple of times before. It's almost like the same process that PP/PB goes through when outside and UV...
  19. Madrab

    Combi install do I need an external ABV?

    No - if the pressure is the system is stable then it's nothing to do with the boiler being oversized and the pressure getting too high If there is a rad with 2, always open, lockshield valves then that would be more than enough to act as a bypass ensuring min flow through the boiler on overrun...
  20. Madrab

    Lead pipe removal - proof for water company

    Even if it's to be moled, 2 holes need to be dug, one at the output side of the toby and another at the end of the run where the pipe will then enter the property. So the first hole at the mains chamber can be dug down and the pipe exposed, showing the lead. The question already asked though...