Search results

  1. B

    Quick advice please - Unvented Cylinder on Y-Plan

    Ive got a retro fitted Megaflow, running on a Worcester Bosch Greenstar RI gas boiler. When the Megaflow was install it appears they kept the Y Plan heating system in place, however, they have not added in a thermal cut out valve on the primary flow to the coil. My question is, once a...
  2. B

    Step by Step process for removing an external wall

    Hi All, Just a quick one for the more knowledgeable. Before I start I should like to point out that I am not doing the work myself, just being nosey and wanting to have an understanding before the builder takes over. I have had a look for an "order of process" on here but couldn't find one...
  3. B

    OSO 20 RI Unvented Cylinder

    Hi guys - went to customer today, pushing out boiling water through Temp relief valve, looks like cylinder stat isn't working as motorised valves both seem fine. However, upon looking at the cylinder there didn't appear to be a high limit stat fitted anywhere - or any other means of...
  4. B

    Help Identifying Programmer

    Hi Guys - any ideas on make/model of this? Thanks
  5. B

    Cowboy Trap

    Did anyone watch Cowboy Trap last night? Made me laugh... one of the major huge "issues" that the plumber had done wrong was keep the bathroom tap (on a refurb) tank fed - he was installing a non dual flow basin mixer tap! Which the customer purchased. They made a huge issue out of how it was...
  6. B

    Leak in screed - moving central heating pipework into loft

    Hi All, some help please: As the title says, moving central heating pipework out of screed and into loft, with drop downs for rads. System is open vented, with cylinder, pump & mid-position valve all in airing cupboard. Boiler is a Potterton Netaheat - wall mounted in Kitchen. All...
  7. B

    Ideal Minimiser SD 80 - power output?

    Hi Guys, Customer called me and wants to add a rad (or underfloor heating) into their new conservatory being built. Been told over the phone that their Boiler is a "Ideal Minimiser SD 80" anyone heard of these, done a bit of research on here but not come up with anything. Am looking for...
  8. B

    Queston re. Boiler

    Hi Guys, Customer called me and wants to add a rad (or underfloor heating) into their new conservatory being built. Been told over the phone that their Boiler is a "Ideal Minimiser SD 80" anyone heard of these, done a bit of research on here but not come up with anything. Am looking for...
Back