Search results

  1. N

    flexible hose

    hi . cooker hose on hob behind electric oven.no leaks, no signs of distress. mimimum ncs, AR though even with no signs of distress?ta
  2. N

    britsh gas f'''ers!!

    did a landlord check 2 months ago. landlord phones me saying bg came out , at risked boiler saying it leaking co , said he "needs a new boiler" quoted 3k for combi swap a alpha 240!!! told the landlord it room sealed and if it was leaking it can only be flue and case seal ( which were visually...
  3. N

    gas checks for hips?

    hi guys we all know how great landlord checks are for keeping the revenue ticking over. but i cant help thinking if the government were so concerned about gas safety how can it not be a legal requirement to have a gas check when purchasing a house? do you think private houses will have to...
  4. N

    co on ecotecs and greenstars

    hi. im relatively new to gasbut something just dawned on me while servicing. eoctec plus ecomax and worcester greenstars. if poc air leaking back into the air intake since theres no case seal ( unlike the cheaper ecotec pro's and glowworm cxi sxi isnt this potentially lethal? i cant believe they...
  5. N

    boiler manufactures

    ive been looking around at jobs with baxi, valliant, bosch. was just wondering is the repairs here only concerned with boilers themselves or do they repair rad's exterenal conrols etc? baxi have alot of good stuff said about working for them. monday-friday hours? cheers
  6. N

    co incidents

    hello. i read the co incidents on the hse website. does anyone know were to get info on incidents/causes for past 3 years? also does anyone know where i can obtain info on co incidents involving condensing boilers? corgi tech page only has valliant seals being recalled but not much other info...
  7. N

    combustion test caps

    does anyone know where you can buy the black rubber combustion test zone plugs found on vaillant turbomax 824,828. and also where you can buy the combustion test point caps on the flue for worcester greenstars? i susupect theres quite a few of these missing so want to stockplie them instead of...
  8. N

    servicing v breakdown contracting

    im curious about something. theres guys in our firm who are subbies and only do servicing 22 quid a service 8-9 an avergae a day. however theres subbies who do breakdowns. im curious as to what are the possible advantages of doing subbie breakdowns( i cant see any) collecting parts, fitting...
  9. N

    sludged exchanger

    hi .a sludged heat exchanger. would the boiler make kettle noise and what would be the expected temps of flow and return pipes in such a scarnio? just trying to discover how i can recognise this problem on site. thank you chaps and merry xmas
  10. N

    gas drops

    passed the acs which was fine. just wondering about something which i just never enquired about. how come you are not allowed a drop of gas of say 4mb on u6 meter on pipework but with appliances connected (no smell_)you are allowed this leak/drop?? seems amazing you can have 4mb leak with...
  11. N

    gas rates combi

    good evening. im due to to take the acs in 4 weeks time and would like some advice. got my portfolio done but the guy i trained with does mainly installs and a bit grumpy!! combi badge says min rate 7kw max rate 25 kw. run hotwater and get 20kw. do inlet working pressure test on boiler reads...