  1. C

    baffled power shower not getting to temp

    thanks seco the shower is a Triton AS2000x i found a small bore ballafix valves on the supplys changed the hot one to large bore and run some hot into a container maybe ill run some more off just to double check
  2. C

    baffled power shower not getting to temp

    thanks Picasso checked hot & cold and are correct to spec
  3. C

    baffled power shower not getting to temp

    hi i replaced a power shower like for like and the hot water is not getting as hot as it should the cold feed is direct from cold water storage tank the hot feed is direct from a surrey flange at the cylinder if i turn off or turn right down the cold supply the hot water gets lovely and hot...
  4. C

    What would you do....

    you can check on the gas safe register ask him for a certificate or registration number and why now after job is complete and payment is made,just curious
  5. C

    Weaping pressure relief valve - Worcester greenstar 30si

    yeah good idea if you release that prv & try and get rid of that leak sealant you have put on it-its a safety valve for your boiler and protects your system if you block it up and overpressure again just think what it could do to weaker parts of your system if you turn power off (no reason...
  6. C

    toilet not flushing properly... blocked u bend or syphon ?

    hi it sounds like you have a blockage in your soil pipe-check the nearest manhole to the toilet if you have one this might be blocked(saves taking out pan) then if the manhole is ok a good plunge in the toilet with a drain rod or plunger usually unblocks it 98% of time-if toilet is new,has it...
  7. C

    FloPlast 110mm PushFit - Taking it apart?

    and when you reassemble it-use lubricant and it will come apart easier in future
  8. C

    Polypipe Conduit Pipe

    can you explain a little more please are you struggling with floor levels once laying the pipe-what sort of system are you planning on using you can get trays for pipe to clip into you can get pipe clips avoid having joints under floor unless you can access them easily you can get 12mm...
  9. C

    heatslave high limit

    cheers burnerman i've set psi to manufactures instruction-using a gauge-thats how i knew psi was set too low in first place analyser was showing all correct readings maybe a coincidence on stat- seen client today - and said all was fine - i will play this one by ear and recheck shortly...
  10. C

    One or two bottle air vents?

    hi john some automatic air vents should not be left in the open position all the time, check manufactures instructions,-& check manufactures instructions on your unvented hw cylinder to see if you need the two,as long as you check it every now and then you should be ok,i would'nt bust a gut to...
  11. C

    heatslave high limit

    just a couple of things missed off the last entry the boiler has only been in hot water mode the heating pump was checked and the boiler was vented by all manual air vents cheers guys
  12. C

    heatslave high limit

    hi guys another oil problem had a burner keep locking out,gave it a good clean up and new nozzle client said it was great had no further calls bumped into him today and he said keeps locking out on high limit (over heat stat) only thing i can think of is when checking pump pressure-it was...
  13. C

    high flue temperature

    hi guys i have just changed a nozzle on a oil boiler,like for like and now im getting too high flue temps 100 more than before i have correct co2 & the right psi the air set up is lower than in the book- when raised messes the co2 excess air is around 44 and 80 + effficiency all off memory...
  14. C

    Leaking shower

    i would get the plumber back to rectify his problem-or give you the money back you have already paid him from the shower valve to the shower hose outlet fitting- pipe work needs to be checked if buried in wall -cap off shower out let (before hose)and turn on valve- if pumped shower after...
  15. C

    Gravity to fully pumped and CH zoning

    personally i would of had a stat upstairs considering you have zoned it i don't know why anyone would put a 15mm pipe into a cylinder if i wanted to throttle down the flow i would of put in a lockshield valve in (a gate valve without the head - primaraly to stop people tampering)and also the...
  16. C

    15mm pipe ok for everthing in bathroom?

    i think what ben is trying to tell you-it depends on the size of your incoming cold water main at the end of the day the cold goes into your boiler in 15mm and comes out in 15mm and most cwm are in 15mm internally i would personally use 22 where i can-shortest possible routes(i have heard...
  17. C

    Bathroom install....any tips?

    you have done a lovely job on your kitchen well done i can't sleep at night any more knowing i have used all that pva with everything, get the foundations right and hopefully the rest should fall into place nice square flat walls are always a good start as long as you have the time and...
  18. C

    greenstar wiring - frost stats and controls

    thanks guys for your help ill be gutted if i have to change the receiver again,i replaced it about 6 months ago its not the 1st time and sure not the last cheers
  19. C

    Bathroom install....any tips?

    test all pipe work before making good and tilling and who said do not pva walls before tilling i reccomend putting a batton around wall for bath to sit on, to stop any future movement silicone on batton silicone around top of bath before tiles dont use cheap tile adhesive & grout &...
  20. C

    Triton Thames (exposed) Thermostatic Concentric Mixer Shower

    i believe triton have a 5 year warranty on valves how old is yours if older speak to tech and they will send service kit with instructions or advise you-not too hard to change