    Halstead Ace High ignition problem

    just out of interest is there a little black plastic nub on the top right hand side of the boiler?
  2. E

    Glow Worm 24cxi hot water problem

    hows the diverter motor? i have had a few of them constantly motoring back and forth which causes the symptoms you have described. it especially effects the hw as it runs hot then lookwarm/cold constantly.
  3. E

    Baxi 105e , water hot in the pipes but cool out of taps

    if you have isolation valves for the different mixer taps. try isolation each tap one at a time, run a hot tap and see if it gets hot. once you find the faulty mixer you can keep it isolated until its fixed/replaced.
  4. E

    British Gas Worcester C1 combi boiler - pressure always high

    Does the pressure reach 4 bar all the time or only after the heating has been on for a while? if its only after the heating has been on and if they have to constantly recharge it on every ASV and sometimes inbetween then there is a good chance the expansion vessle is faulty or the tube...
  5. E

    glow worm 30cxi

    if the overheat stat needed resetting it would display F5, since its displaying anything i suspect you either blew the fuse on the pcb or blew the pcb itself...which isnt cheap! either way get someone in.
  6. E

    Tribune Unvented hot water cylinder Water Overflow dripping

    does it drip constanly or just when the hotwater has fired if so the expansion vessle may need charging. if its 24 hrs a day then you may need a new flow limiter. hope this helps
  7. E

    knocking down walls...is it load bearing

    may be answering my own question here but lifted a few floorboards in the bedroom after work and can see the top of the downstairs wall...had head down there and cant see anything actually touching the top of the wall so surely this isnt supporting anything?
  8. E

    knocking down walls...is it load bearing

    i was hoping to knock down the wall between the kitchen and dinning room in my 1970's house to create a bigger kitchen, the wall in question is blocks, but none of the upstairs joists seem to rest on it, they run inline with the wall, infact the only thing that seems to is a stud wall directly...
  9. E

    Ideal Isar HE30 Leaking, Diverter Valve Not Closing

    probably be easier just buying a new divertor catridge than trying to clean up the old one, not to expensive either
  10. E

    BG 330+ = which Worcester Bosch boiler

    worcesters are still badged up as rd532 by bg
  11. E

    Installing a new boiler

    bg 330+ is a rebadged glow worm...sure he didnt say the 532 thats a worcester
  12. E

    Worcester Bosch 28i Junior: hot water but no central heating

    could be the divertor motor stuck, had a few of the earlier motors on them need replacing
  13. E

    Vokera Flowmatic 20/80 rs no hot water

    i have been having trouble with this for a while, i can only get hot water when the boiler is in CH mode. i have replaced the diaphragms in the CH manifold and DHW manifold but no luck. i have noticed that when in CH mode the spindle in the CH manifold moves and breaks the micro switch however...
  14. E

    Vokera 20/80 rs flowmatic problem

    i have a vokera 20/80 rs flowmatic, i have just changed both diaphrams however now the DHW will only come on if the CH is running. the CH runs fine on its own but the DHW will not make the switch on its own. i have bled the DHW vessel and made sure that the spindle on DHW is moving freely, if i...