Search results

  1. S

    Geberit Duofix or Grohe Rapid SL WC frame, which is best?

    Hi I'm looking to buy one of these WC frames, any recommendations or benefits of one brand over the other? Geberit are a little more expensive, but there isn't much in it. Thanks
  2. S

    Replacing internal 40mm doors with 35mm doors

    I have two pairs of internal French doors that need replacing. The doors are 40mm thick and are a matched pair at 78"x48" with rebated styles. The doors I would like to replace them with do not exist, the nearest is an XL Joinery matched pair that only come in clear glazing, not obscured...
  3. S

    New external door and exposed cavity- to fill or not to fill

    Morning I have had a set of french doors put in where previously existed a window. The house is about 17 years old and has a good size cavity. Trouble is the cavity appears on the inside of the house and I am not sure what to do with it. I am having the floor tiled in a couple of weeks...
  4. S

    Damaged anaconda

    Hi Just been ripping out a [flood damaged] kitchen where the gas meter is rather stupidly placed on the floor located inside a rather botched cabinet. In my fervour to remove the ceiling a big lump of board came down on the meter and bent and holed the anaconda on the meter. The gas was...
  5. S

    Gas pipe to a Worcester System 24i boiler - nice job

    Hi I came home from work to find a good length of 28mm copper growing up an exterior wall. Obviously this new 'feature' pleased me greatly, have a look at the picture: Fair enough I decided to relocate the boiler to the opposite end of the house, but to slap this up the exterior wall...
  6. S

    Got a shower pump getting a Mega flow, will the shower work?

    Hi I am getting a Megaflo installed in a couple of weeks time along with a new boiler etc. It just occurred to me the shower in the bathroom is pumped and has a little electric on/off switch. What will happen when the old cylinder/headers tanks are ripped out and the Megaflo goes in...
  7. S

    Megaflo or Range Tribune?

    Hi I have had 3 prices for a new heating and hot water system. Two of the heating engineers have quoted for a 300ltr Range Tribune, one for a 300ltr Megaflo. Can anyone offer advice on the benefits or otherwise of either brand as there is a cost differential? Thanks
  8. S

    22mm or 15mm cold water feed to Megaflo?

    Hi I have had three heating engineers around to quote for a new boiler and megaflo system. Two have stated I need to put a 22mm feed to the megaflo, one has stated 15mm will be OK as the pressure is fine, but 22mm would be the ideal. Can anyone comment/advise as to whether I need to...
  9. S

    Internal wall demolition, catnic, needles and stand props?

    Hi Looking to knock through an internal wall. The wall is single brick and extends upstairs but does not support any roof structure. I am looking to generate a 2m apeture and have been advised by my architect that a 2.4m catnic lintel will be sufficient to take the load. Can I simply...
Back