Search results

  1. A

    Ideal C28 mini - Faulty CH Temperature probe?

    Update you anyone googling this in years to come. I drained the boiler down and replaced the temp probe. And now it works! I also removed the dhw exchanger while I was at it. Now running like a dream!
  2. A

    Ideal C28 mini - Faulty CH Temperature probe?

    If I have to drain down, as the boiler is at the highest point can I just drain the boiler down? Shutting off the ch flow and return first? Shall I replace both temp probes? And advice on filling it back up? Re open valves and then fill using loops?
  3. A

    Ideal C28 mini - Faulty CH Temperature probe?

    Update.... I have just bought 2 of these ready... Some advice on how to replace it would be great. To drain or not to drain? To put paste on or not?!
  4. A

    Ideal C28 mini - Faulty CH Temperature probe?

    Hi all, Long time no speak! Since replacing my PCB ignition board, the boiler has been running like a dream! Recently, I have noticed that after the boiler has been running for a time, it starts cutting out...stops for a bit, fires up again then sometimes runs for a bit or for 2 seconds! It...
  5. A

    Bathroom floor uneven for vanity units

    Hi all, I am currently installing the new vanity units (basin and toilet units. They are 2 different units which sit next to each other. The sink then plops on top of them both. This is the pic if it helps. My problem is the the floor boards are not level - They have been hacked about so...
  6. A

    Tiling onto concrete render (one wall flat, other not so...)

    thanks ever so much. That makes me feel better. I will take your advice!
  7. A

    External breeze block wall - board or plaster?

    What a gent. Thanks ever so much. The pictures really help to see how to put the board adhesive on. Thanks very much! Getting it nice and plum could be the tricky bit!
  8. A

    External breeze block wall - board or plaster?

    Hi all, In the bathroom I have just ripped the tiles off the external wall. Unlike the other walls, this was boarded with plasterboard and now I have ripped that off all I can see is the breeze block. The plasterboard was just glued to the wall. Is that normal? I will be re-tiling it...
  9. A

    Tiling onto concrete render (one wall flat, other not so...)

    Hi all, When ripping down the tiles, just the concrete render was left. It is relatively flat, so I'm thinking to just tile on to it. I've heard, as long as I use a cement based adhesive I do not need to prime it with anything... but others say i should (not PVA) However, there are some larger...
  10. A

    Soil stack leaking?? New fit bathroom - Video explains better!

    Just to confirm... It is rain water. I tied a tissue around the stack (above the joins) and it is wet. And is has been ****ing sidewards today. Must be getting in in certain wind conditions
  11. A

    Soil stack leaking?? New fit bathroom - Video explains better!

    Awesome! I think you are right... I have never seen one like that.. Nice to know what is is. Should I be replacing it all? with some more conventional joints? e.g the one that has the pan waste and basin and bath waste in one? Im guessing it would be difficult as the stack is obviously fixed...
  12. A

    Soil stack leaking?? New fit bathroom - Video explains better!

    I've just stuck my finger in the wet bit around the 'joining' bit, and yes its wet, but the brown sludge does not smell. Is it rain water? Maybe coming in from the tiles? Here is a pic of the brown wet stuff! PIC
  13. A

    Soil stack leaking?? New fit bathroom - Video explains better!

    Link to pics and vids This video is the most helpful https://drive.google.com/open?id=1VQjssJwQOb7LxhLUsaYGRM3GP_I827Io Hi all, Time for a new project. The wife wants a new bathroom - basically same layout but with vanity units. Our soil stack is internal and boxed in to the corner of the...
  14. A

    Diverter actuator problem? or pin?

    UPDATE !!! I finally just went for it and I replaced the Ignition PCB... and it now works! Just thought its good to get a solve to the mystery. Hot water and heating when I want it for the first time in 4 years!
  15. A

    Ideal Mini ignition PCB?

    UPDATE !!! I finally just went for it and I replaced the Ignition PCB... and it now works! Just thought its good to get a solve to the mystery. Hot water and heating when I want it for the first time in 4 years!
  16. A

    Ideal Mini ignition PCB?

    Hmmm Ok, that is fair enough - I would not touch the combustion chamber myself anyway. I needs a service anyway so I will pass on all the details to Gasway. Are you able to tell me what you think the common fault is so I can tell him - might save some diagnosing time, if he can go straight to...
  17. A

    Ideal Mini ignition PCB?

    Hi, I have just checked, and I can confirm when it does not light it does NOT click. When it DOES light, it does indeed click just before it lights!
  18. A

    Ideal Mini ignition PCB?

    I will put my ear next to it, the next time it stops working. Many thanks
  19. A

    Ideal Mini ignition PCB?

    Hi all, Hope you can help! I have an Ideal mini c28 Combi boiler Have been doing a bit of work recently; I have changed the diaphragm in the diverter valve (split) and cleaned out DHW heat exchanger (wow the muck that came out of that!!). So it already works 50 times better than before...
  20. A

    Diverter actuator problem? or pin?

    Hope this makes sense, and thanks in advance for reading. I have had issues with my boiler for ages, so finally got round to sorting it. I replaced the diaphragm of the diverter valve and cleaned it out and cleaned the Heat exchanger - I know have hot water for the first time in 4 years!!! CH...