  1. S

    vaillant combi turbomax pro 28e

    What indicators on the boiler flash? what colour?
  2. S

    Heat Line VISO 24 DHW Issue

    Why thank you Paul :) I'm just trying to learn - and have never heard of that one before that's why I asked. I'd have checked the DHW thermistor as mentioned by another poster first - as well as the flow switch was working properley when a demand was made/water runs cold - then there's the...
  3. S

    Heat Line VISO 24 DHW Issue

    sorry of course - I see.... so obviously if not then a partially blocked plate heat ex possibly
  4. S

    Combi boiler hot water problem

    sounds like a flow switch/diverter valve problem (depends what boiler it is) - that only makes contact with the switch when opened fully / more flow etc
  5. S

    Heat Line VISO 24 DHW Issue

    :? was just trying to work out what that'd prove
  6. S

    Potterton Suprima 60L keeps turning off with Green Flashing

    I'd check the impeller is all ok and not blocked or loose - ryou need to emove 4 allen key screws to check that - after closing is valves or removing as mentioned by petit_pablo Also check coil resistance
  7. S

    Heat Line VISO 24 DHW Issue

    Is this to check the plate heat exchanger is partially blocked up Agile? ...
  8. S

    Potterton Suprima 60L keeps turning off with Green Flashing

    try bleeding a radiator at top floor level and see if water keeps flowing, if not could be a blocked cold feed, if there's water in the header tank. also could be some air in the system so check that too petitpablo: if air was in the system or a lack of water would that not cause an...
  9. S

    No hot water from Worcester 25Si COMBI

    DHW Thermistor ok? if as suggested a flow issue, check any filter/cartridge in your boiler on the cold inlet (that supplies the hot water to your hot taps) has not clogged up and resitriced the flow.
  10. S

    ideal mexico 40/60 boiler, no hot water ??

    IF HOT WATER ONLY IS ON AND THE PIPES GET HOT TO THE HOT WATER MOTORISED VALVE - AND UP TO THE CYLINDER - IS THERE AN AIR VENT TEE'D OFF THE FLOW PIPE TO THE CYLINDER??
  11. S

    ideal mexico 40/60 boiler, no hot water ??

    star from the bginning logically: when you select hot water only does the boiler and pump run?
  12. S

    Warm water from hot water cylinder.

    What was the cylinder stat setting set at?
  13. S

    Joining combustion chamber question...

    Quick question - I am trying to learn about boiler fault finding. I am gas qualified (since June) and have been working as a plumber for approx 3 years. I am working 1 day a week with a gas engineer (doing breakdowns/gas safety's/services etc) - would it be possible for me to join the...
  14. S

    Baxi solo 2 overheat

    check the pump and vent all air vents/rads in the system. make sure boiler stats is not set too high and also check water level in system is correct (vent highest rads and see if water squirts out) - does the boiler overheat after a certain time?
  15. S

    Potentiometer question on PCB

    thanks a lot Kev for your help I really appreciate it. Have you missed a part of this post out about the gas valve or is it just my eyes playing up tonight :lol:
  16. S

    Potentiometer question on PCB

    Thanks for your help Might sound stupid, but if you alter the potentioemeter from the inside (ie removing PCB cover to access them, not the knob side - will this make a difference, or will it do the same as turning the user control dial which also connects to it?
  17. S

    IDEAL HE 35 Boiler L 8 Code No Heating No Hot Water

    Is this an Ideal Isar? If so, I think it's a Fan error fault
  18. S

    Potentiometer question on PCB

    Thanks Kev - so basically by turning the control know ie CH, you allow more or less resistance to get through to the CH thermistor?
  19. S

    Potentiometer question on PCB

    Hi Just a quick question - most PCBs contain potentiometer's - eg CH or DHW pots - what exactly do these do? I know they can be adjusted but was just trying to work out what they are for? When you turn the CH dial for eg on a combi - does this in effect increase/decrease the...
  20. S

    CH not working when HW/CH selected on programmer

    a valve on the return pipe from your h/w cylinder as in the picture above by D Hailsham