  1. L

    Floating floor repair..

    Yep but keep in mind that the toilet base will be secure to the floor along with the wall so I don’t want the floor to be moving due to not being secure to all edges. if it means spending £80 to make sure it’s not going to shift then I think that’s £80 well spent to be honest. I’m not one for...
  2. L

    Floating floor repair..

    So here is what I’m thinking of doing. First of all, because the floor was tiled it means I have 6mm gap between current wall tiles and the floor since the tiles have now been removed and are not going back down. I fill in the gap with new chipboard 18mm to match current chipboard. Next I apply...
  3. L

    Floating floor repair..

    Here are some pictures.
  4. L

    Floating floor repair..

    Hello, I have a floating floor in my downstairs toilet area which due to a small water leak that remained undetected has damaged a section of the floor to the point i now have a hole that is about 2ft x 3 ft wide. Underneath the flooring is polystyrene blocks so there is no joists in which to...
  5. L

    Whole house pump

    Hi Andy that makes sense so now I need to look at how easy it is to fit the flange in place of the current connection. Not sure I have enough room in front of the h/w cylinder to fit the pump, as such I’m looking to raise the entire h/w cylinder two feet on a wooden platform and then put the...
  6. L

    Whole house pump

    Hi Andy, yep know about the separate h/w value so as to stop air circulation. my main concern was the expansion pipe in that what do I do with that. If I do nothing and the pump is plumbed into the entire house then the water is going to escape through the expansion and into the header tank...
  7. L

    Whole house pump

    Hello, I have a gravity fed water system that feeds two shower heads from a tank in my loft. Hot water feed for the showers is fed from regular indirect hot water cylinder that is heated using a regular gas boiler. The water pressure is not great on the showers both cold and hot feeds. The cold...
  8. L

    Vailliant eco TEC plus 430 Heating up when no call

    Thanks Ian, it looks to be working fine for now then. Call for Heat only and it moves to H position, call for water only and it moves to W, call for both moves to mid-position which now makes sense. What i didn't expect was that it remains at last position when all calls for heat are removed...
  9. L

    Vailliant eco TEC plus 430 Heating up when no call

    Yes sorry, 3-port value is correct.
  10. L

    Vailliant eco TEC plus 430 Heating up when no call

    ok, so here's the thing. If neither the water or the heating was making a call for heat i would have thought that the 2 port value would not come into play here. Today I inspected the 2-port value and when i make the call for heat it moves over to the Heat position but when i stop the call for...
  11. L

    Vailliant eco TEC plus 430 Heating up when no call

    I have a Vailiant 430 and today for the first time I turned the heating on due to it being cold. I found that after a while the heating was remaining on despite the Nest having been switched off. I went to the boiler and found the radiator symbol flashing which I understand means its active. I...
  12. L

    I-on40 RF Failure

    Found the following which worked. Go to the keypad you want to use for initial configuration. Obtain an address for this keypad by pressing and holding A and  keys simultaneously for at least three seconds until you hear a sound. The display shows the address allocated by the control unit, such...
  13. L

    I-on40 RF Failure

    Hello, Panel replacement arrived but shows i-0nh04+ so slightly different. Wired first keypad but when powered on the keypad just displays ' Press addr button(s) on wired keypad. Press buttons but no good. Addr set to zero (all addr jumppers off). Anybody any idea? Les.
  14. L

    I-on40 RF Failure

    Jamming not being reported but that did come up a few weeks ago but then cleared on entering Installation mode. All batteries check fine and all voltages at the panel are good. The system is about four years old so now out of any warranty. Haven't spoken to Eaton, not in the trade so they...
  15. L

    I-on40 RF Failure

    A couple of weeks prior we had multiple RF device failure which cleared after a power down reset and i'm now wondering if this was the start of a RF failure.
  16. L

    I-on40 RF Failure

    Mains was powered down while battery was replaced. Tried full power reset but still shows RF failure. Going to try full factory reset tomorrow to see if it clears the fault otherwise I think its a new panel at £170.00
  17. L

    I-on40 RF Failure

    Tamper when trigged on any radio device is not detected on panel. Doesn't have an expander fitted, wireless feature provided onboard as per standard i-on40. Les.
  18. L

    I-on40 RF Failure

    The battery i replaced was for the alarm panel not for a sensors, all sensors that are failing. The web browser shows that no signal is being picked up from any of the sensors and it appears that the alarm panel its self is not able to work on the wireless part. Even when i go in and mark all...
  19. L

    I-on40 RF Failure

    Update...Marked each RF sensor as Unused but alarm will not set due to rf failure. Thought is may have allowed it to given there was no RF devices configured. Does anybody have any clues as to what could be the cause, hoping its not a hardware failure on RF part of the alarm but looking like it...