Search results

  1. J

    how can i protect an outside gas pipe?

    i would of ran it higher. if not shorten the clip spacing or if worse can to the worse ran it in steel (LCS) all the above means adjusting the gas run which i dont recommened. all i would say is make a boxing round it
  2. J

    hot water pressure dropped

    if it effects all your hot taps then it might be a filter issue, it will be inside of a combi boiler and on the balancing valve on a unvented h/w set up on both refer to manufactures instructions, alot of them arn't located in side the burner chamber so you should be alright
  3. J

    Worcester 24cdi lukewarm water

    start saving for a new boiler or at least a gas engineer to do it because they leak like a siv after if you don't replace the o-rings and washers
  4. J

    Worcester 24cdi lukewarm water

    yer just after posting this i had a quick look at one and i remember the small little screw which you have got to bend open the clip, put it in, put some white paste on it :wink:, then try and bend it back round the pipe while getting covered in white paste and screwing the screw up without...
  5. J

    Potterton Suprina 50Locked out and very hot

    flick the immersion heater on and call a gas engineer in the morning. EDIT: *removed rest of post* not complying with rules
  6. J

    Worcester 24cdi lukewarm water

    if your heating pipes arnt getting hot from under the boiler then it either blocked heat exchanger or hot water thermistor is on the blink (normally around £6) and takes 5 mins to fit, worth a try first Change hot water thermistor (in pipe) Turn boilers isolation switch off turn water off...
  7. J

    ...Ideal isar he24.....

    I think you will find that the diaphragm has split or the spring in the diverter valve is on its way out, it will only get worse in till repaired and the heat will start heating upstairs rads instead of heating your hot water
  8. J

    Vaillant Flue Fall - With Pic

    yes they do have the collars mixed up looking at it that flue will JUST be connected. ask to see the analyser print off on a vaillant i normally get around 0.003 with around 57-80ppm. Your boiler hasnt yet been commisioned due the stickers are still stuck o the top off the boiler :D as...
  9. J

    New boiler relay (hive home)

    move orange to pin 3 if i under stood you correctly. Switch Live comes back to L2 (L1 is a additional live )
  10. J

    Vaillant Flue Fall - With Pic

    If that elbow is fully pushed in then that collar doesn't fit round, that is why they send a shorter one with a horizontal flue. If you undo that collar just enough so the foam pad starts to come away and look in the through the gap I can guarantee its not completely push in. He has used the...
  11. J

    kitchen sink

    easy really, flip your new sink upside down put it on the worktop make sure your new sink covers the old hole/s draw a line round it. measure the distance from the rim to the lip where your brackets fit on to then and draw this round your mark on the worktop and this is your line to cut round i...
  12. J

    new 25 mdpe main question

    i have a customer who has asked me to bring a new cold main in his current main is 1/2 steel suppling a 4 bed, 2 b,room and cloakroom kitchen and utility, im part off the wiaps so i know the in and outs off new main My question is that can i take the new main to the from the new stop valve...