    Emergency lighting in Multiple Occupancy Properties

    Hi All Can anybody advise me at what point is emergency lighting legally required for a multiple occupancy property example: Students sharing a 3 storey house. Is it based on number of floors, number of occupants etc ? Many thanks Mark
  2. M

    Combined bathroom ceiling light and radiant heater.

    Are these monstrous things still available ? Have a customer who seems to think so and wants one replaced. Cheers Mark
  3. M

    Found this open in a cupboard. Ouch !!

    I know we all love pictures so heres one from today's job. Could have been nasty while putting the hoover away !! No nut and bolt holding it closed, just flapping about open. Just done PIR and found this. Am I right that this fusing of the neautral is no longer safe practice ? Must be...
  4. M

    Max disconnection time for electric shower

    Sorry guys, pretty sure it's 5 sec but damned if I'm going out to van for book in this weather. Can anyone remind me. Thanks Mark
  5. M

    PIR RCD query

    Hi all PIR today. TT setup. 100mA RCD , Socket outlets on RCBO's. RCD not time delayed. What code would you give this. Was thinking code 2. Cheers for any feedback
  6. M

    Routing of cables

    PIR on an existing installation. How can we confirm definately that all cables are routed in prescribed zones or with necessary mechanical protection when they are out of sight in the fabic of building ??? Not 100% happy ticking this box on this job. Do you guys put it down as a LIM if not...
  7. M

    Dual RCD Consumer Units

    Heard a mention of these but can seem to find a supplier. Anyone use these ? Recommend a good make ? Cheers
  8. M

    Adding 30mA RCD protection.

    What are the options for providing 30mA RCD protection for all socket outlets on an existing TT system that has only a 100mA RCD covering all circuits. Not a split load board. Many thanks.
  9. M

    Earth Clamp on TN-S

    Just completed a c.u change and upgraded the undersized earth conductor . The clamp on the sheath was a standard BS951 earth clamp. Under the impression that if the supplier has provided this then it is ok. If not is there a suitable replacementt available. Z's were all ok but having an assessor...
  10. M

    Napit or Not

    Hi. Newbie post be gentle :) I have my own gas and electrical safety testing business ( one man band ) Have Corgi reg and Pat Test C & G. Just completed 2381 and starting 2391 next week. I have been doing P.I.R's for letting agents for about a year and in the current climate felt it would be...
  11. M

    Advise on qualifications needed.

    Hi all. I am a Corgi reg gas engineer and I am looking to provide an electrical safety testing service for a large domestic letting company and maybe complete some minor works too. What are the qualifications I would need ? I am looking at getting my C & G 2391 and Part P. Is this...