Search results

  1. L

    en suite odour

    Our ensuite has a wc, hand basin and shower. Ive checked and double checked the traps on numerous occasions, and they always have water in them. There is no apparent leaks & the soil pipe runs internally. Is there any suggestions or advice on where this drainy smell is coming from...
  2. L

    Smell

    6 months ago we moved in to our newly renovated house (every room was changed) Just recently we noticed a terrible smell from our on-suite. Got a plumber friend to have a look at it. It turned out the soil pipe (internal) where the shower and basin wastes run, wasnt vented so he swapped...
  3. L

    Hot Water not Hot enough!

    We have a system boiler (glow worm) The water is set to come on an hour in the morning and an hour in the evening. the boiler definately fires up, and both pipes get hot (very hot) from the boiler end, right up to the cylinder. The cylinder thermostat seems ok as initially i turned this...
  4. L

    storage tank?

    The water pressure in my pub is really poor. One example is if two toilets are flushed they seem to take forever to fill. I have chased it up with the water co for months now, but no joy of any improvement. An idea we had was to put a storge tank in the loft and soley just feed the toilets...
  5. L

    boiler wont turn off

    hi, I have a glow worm 30 sxi system boiler, the main circuit board was damaged so i have replaced recently all was fine until we have noticed that when the heating or water is meant to be off by the timer or manually the boiler keeps running. any suggestions to this problem will be...
  6. L

    Mixer Shower

    Hi there We have two tank fed mixer showers in our house (gravity fed not pumped). The one in the main bathroom is fine, however, the one in our en-suite will not produce any hot water whatsoever. Are there any recommendations or tests I can do to eliminate the problem? Thanks in...
  7. L

    emmersion

    The emmersion heater has stopped working, is there a way of knowing if we just need to change the internal thermostat (which must be easier) or the whole element its self? any advice welcome cheers
  8. L

    shower pump

    Hi, i am going to be installing a shower pump at one of our properties, and was just wondering if it is posible to run two showers off the one pump? As I thought whilst Im in the loft i may as well increase the pressure for both ot the showers in the flat. Are there any makes/brands to be...
  9. L

    w/c leaking, randomly

    A couple of weeks ago the upstairs wc leaked whilst we were out, caused a bit of damage in the room beneath. I went to investigate the leak but couldnt identify where it was coming from, it had appeared to have stopped. but i isolated the water to the cistern as a precaution. the next day...
  10. L

    saniflo

    Saniflo seem to have a blockage as water in pan rises up right to the rim when flushed (can only be toilet paper). is there a special drain rod or chemical we can use to clear it or any suggestions? thank you in advance ++++++++++++ I have deleted your duplicate post. Please...
  11. L

    Water Pressure!

    One of my property's water pressure has recently completely diminished to the point where the upstairs water barely works. In recent weeks water works have been done in the area, I have spoken to the supplier and they're denying it has anything to do with them and have checked the water...
  12. L

    Urinals not working?

    I have recently noticed in our pubs gents, the cistern has stopped stopped working; ie,not filling or emptying. I had a look up there and there's not much to see apart from the water pipe sticking out of the wall with some type of valve attached, there doesnt appear to we any wiring to it(i...
  13. L

    Pressure reducing valve

    The pressure to our house is 9 bar and we have a combi boiler. I am wanting to install a reducing valve as i am putting an on-suite in and the shower we're putting in wont be able to handle this pressure (or the instructions say it wont) The ideal place, i believe is to install it some...
  14. L

    soil stack

    I am wanting to change my current cast iron soil stack into plastic. The cast iron stack is 3 1/4" Dia. is it possible to adapt onto this above ground level? so Im not messing about digging up concrete around the bottom of the pipe. all comments and suggestions appreciated. cheers.
  15. L

    blocked toilet

    The down stairs toilet is blocked (takes about 10 mins to fully empty), now if tryed plunging it from the toilet end and no joy. yesterday i bought some inspection grate lifting keys and some drain rods, and tryed rodding it back towards the toilet, again no joy. Is there anything else I...
  16. L

    new bath leak!

    Plumbed in a bath today, there appearsed to be no leaks what so ever. That was until i filled the bath, then emptied it, then a tiny drip appeared under the bath, but 2-3 inches from the waste, there is no damp from this drip back to the waste, so its not a run. so i thought there must be...
  17. L

    Basin Waste

    I have been doing some work at a hair salon recently and there are two hair rinsing basins there. basically they take too long to empty, now there is no immediate blockage, as i have cleared the 's' traps out on numerous occasions. and the girls have put some drain cleaner down aswell...
  18. L

    air in pump

    Has anyone come across air locks in shower pumps? Cannot at all fathum out what is causing this. Only thing I can think it may be is the connection from the cylinder (think its a surrey flange) Any advice would be appreciated cheers phil
  19. L

    Adding a radiator

    I am in the process of adding two new radiators. my central heating is in micro bore (10mm) (pumped off a header tank) I have found the 'source' the 22mm pipes where all the micro bores T into. just a few questions to put out; When I T into the 22 pipes can i use 15mm pipe instead of...
  20. L

    micro bore solution

    just had a two storey extention built. I have three new rads i would like to add on. the house has a convensional heating system (header tank etc.) linked to a potterton boiler and the rads run off micro bore (10mm). rad No. 1 is just a replacement on a different wall, so think i can...
Back
Top