Search results

  1. D

    Can i fit a grundfos 40-80 415v onto a grundfos 40-80 240v

    I'm not sure why they fitted a 40-80 pump. The pipework is about 1inch or 1inch and a quarter either side of the pump.
  2. D

    Can i fit a grundfos 40-80 415v onto a grundfos 40-80 240v

    The boiler isn't a condensing boiler as its about 15 years old. One last question would a 15-60 pump head be interchangeable with a 40-80 head. I hope so as the body of the 40-80 is completely different to the 15-60 body, that is the thread is a completely different design.
  3. D

    Can i fit a grundfos 40-80 415v onto a grundfos 40-80 240v

    Cant remember the name of the boiler but I know its 120,000 btus. Would a 15-60 be good enough to pum the water round. All the radiators are on ground floor level
  4. D

    Can i fit a grundfos 40-80 415v onto a grundfos 40-80 240v

    Ok so 3 phase is out of the question. That being the case would a grundfos 40-50 be powerful enough rather than the 40-80 version. The system has about 8 column radiators to heat up but no hot water as that is done via a multipoint. Also does anyone know where you can buy grundfos commercial...
  5. D

    Can i fit a grundfos 40-80 415v onto a grundfos 40-80 240v

    If I took the replacement head off the new grundfos 40-80 3 phase pump and put it onto the old pump body could I then incorporate the old electric onto the new pump head so it wasn't 3 phase.
  6. D

    Can i fit a grundfos 40-80 415v onto a grundfos 40-80 240v

    Hi, I need to replace a grundfos 40-80 f250 pump which is a 240v pump. I have the chance to buy the same pump apart from the fact its a 415v 3 phase pump. Would this pump still work, they are both grundfos 40-80 pumps but obviously the old pump has a 240v 3 wire connected to it. Any advice on...
  7. D

    ravenheat csi 85 intermittent problem

    I am a gas safe registered engineer so I do know the regulations. I dont normally work on Ravenheat boilers so I just needed a few pointers as to what could be causing the problem. Any help or advice on this type of problem with this particular model would be appreciated.
  8. D

    ravenheat csi 85 intermittent problem

    I have also tried another gas valve but that didn't work either.
  9. D

    ravenheat csi 85 intermittent problem

    I have a csi 85 which has an intermittent fault. When it goes through its sequence of firing up after the initial spark sometimes the burner will ignite then shut down immeadiately, then other times it wont even light the pilot light electronically. It just tries to spark then shuts down...
  10. D

    Compatible living flame fire with a baxi 552 bbu

    Can anyone tell me if Baxi made a living flame fire that is compatible with a Baxi 552 back boiler. The owner wants to replace the gas fire with a living flame fire and he laso wants to know if the on/off control is at the top of the fire. Any advice would be appreciated.
  11. D

    Adding an immersion heater

    You cant beat a bit of burnt foam lagging aroma on your sausages and Pizza. I sometimes shake a little boss white over the top to give it an edge.
  12. D

    Advice on how to fit an essex boss

    Hi, I want to fit an essex flange onto a hot water cylinder and I need advice on how to this. Obviously you need to drain the tank but what is the process and how do I drill the tank.
  13. D

    Advice on insulating the pitched roof for my loft conversion

    Thanks for the links. How do I determine a cold or warm application. I have already bought the 20 sheets of 50mm kingspan so would it be ok to use the superfoil over the top of the kingspan.
  14. D

    Advice on insulating the pitched roof for my loft conversion

    Can someone direct me to a website that gives you information on what I need to do exactly to insulate my pitched roof. I have 20 sheets of 50mm kingspan to put between the roof rafters. I have recently had a new roof fitted along with vent 3 underfelt. Do I need to install the kingspan between...
  15. D

    Question about flue pipe on a wood burner multi fuel applian

    I am just about to buy a wood burner dual fuel appliance. The flue outlet connection is 5 inch and I want to run an external flue outside and up the wall so that it is 1 metre above the roof line. The cost of the flue for the appliance is ridiculous and so what I need to know is would an 8 inch...
  16. D

    baxi bahama problems

    The low gas pressure is on about 2 m/bar and the high is around 10 m/bar The 2/ m/bar is on the heating and the DHW goes towards 10. It doesn't get chance to modulate because it shuts down in about 10 to 12 seconds
  17. D

    baxi bahama problems

    Hi, I have just attended a property that has a Baxi Bahama combi. The boiler fires up on hot water or heating but then shuts down after about 12 seconds and doesn't fire up again until after 3-4 minutes. The pump is working fine and there is no kettling with the boiler when it fires up. The...
  18. D

    Fault on Baxi 105e Instant

    I have managed to sort it out. I went back today flushed out the primary heat exchanger this time and after good 1 hours flushing i connected back up and the water is now staying constant on the 13.2 m/bar which it should read. After a while the gas pressure does flutuate down a bit but thats...
  19. D

    Fault on Baxi 105e Instant

    I did clean the plate heat exchanger with a strong red descaler, I had the machine on it for 2 hours it doesnt take longer than that to sort it. The hot differencial valve is this a possibilty that the valve is sticking and not allowing the hoit water to circulate round the plate heat exchanger...
  20. D

    Fault on Baxi 105e Instant

    Already flushed the boiler out with a descaling machine so I know its not that, any other ideas