Search results

  1. G

    Brick and blocks on top of steel frame

    Thanks, yes got cavity tray and wall ties on the architects drawings. Just seems like it wouldn’t work (albeit to my untrained eye!)
  2. G

    Brick and blocks on top of steel frame

    Hello I have had a steel frame designed which will support a room above it — the room will be built directly on top of the steel frame (been designed as a steel beam to support inner blockwork, with a flange added to take the outer brickwork) The frame itself is supported by steel columns...
  3. G

    Existing foundations

    Thanks also stevie
  4. G

    Existing foundations

    Cheers Freddie - puts my mind at rest!
  5. G

    Existing foundations

    Hi In a situation where steels have been designed to go into the outer leaf of an existing masonry wall and sit on padstones (where the other end will be a steel frame (goalpost style) which will be supported on pad foundations), would you expect the SE to inspect the existing house foundation...
  6. G

    Thermalites to medium dense

    Hi all My architect specified 3.6n thermalites (internal wall), together with 90mm near full fill in a 100mm cavity to be able to get a total 300mm cavity and meet the 0.18 requirement for cavity walls However my SE has mentioned that I will need medium dense blocks as needs to support a steel...
  7. G

    Weatherproofing fibreboard

    Thanks all for the suggestions In addition to the suggestions, would something like STS no more ply fibre board also work? Thanks Geo
  8. G

    Fire detection and alarm system

    Hi For an extension in the UK, does anyone know if Aico Ei659iRF battery alarms would meet building regs part B, or would I need mains wired? Thanks Geo
  9. G

    Weatherproofing fibreboard

    Hi Can anyone kindly advise what would be the best method to weatherproof fireboard that will form a carport ceiling? Thank you Geo
  10. G

    Pad foundation

    Thanks Tony, really helpful guidance Great forum here and all advice muchly appreciated Thanks G
  11. G

    Pad foundation

    Thanks, it’s a relief to hear that options are available to get the pads as close to the boundary as possible: and will take this forward with SE.
  12. G

    Pad foundation

    Cheers both for the replies, really helpful Was just an initial chat with a SE about the plans and was mentioned about 1m x 1m pad foundation (is to support some pillars/steels to support a floor above) Your explanation of a potential 2m x 0.5m (rather than 1mx1m) gives me some food for...
  13. G

    Pad foundation

    Hi If 1m x 1m square pad foundations have been specified are next to a boundary, and there is no option to encroach 0.50m onto the neighbouring side, what are the options? Would it be: 1) step the pads back onto property by 0.5m, and effectively reduce the width of the extension by 0.5m, so...
  14. G

    Thermalite 3.6n

    Hi To meet the thermal u values on my two storey extension, my architect has specified Thermalite shield 3.6n blocks for the internal leaf My structural engineer has indicated that it is likely I will need a steel ridge beam and he is currently drawing up the designs / plans To put my mind...
  15. G

    Joists for extension

    Cheers 23vc and Woody, really appreciate your replies
  16. G

    Joists for extension

    Thanks both Woody : by joist hangers and a grinder do you mean attaching the hangers into the brickwork? Thank you G
  17. G

    Joists for extension

    Hi I’m just wondering what is the best method of fixing floor joists for a two storey side extension? Would it be best to fix a timber bearer to the existing gable end of the house and add joist hangers to support the floor joists at that end and then build the other end of the joists into...
  18. G

    Log burner - building regs

    Hello I will be submitting full plans for building control for an extension As part of this extension I wish to put a log burner in it - am I able to add that to the plans and effectively get building control to sign that off at the same time as the extension (I.e under the same application) or...
  19. G

    Padstone on outer wall

    Thank you all for the detailed replies, it’s really appreciated and helpful so thanks! Cheers G
Back
Top