Search results

  1. J

    Can I have a copy of the pdfs Mario please? Thanks [email protected]

    Can I have a copy of the pdfs Mario please? Thanks [email protected]
  2. 41233DE4-8906-43E5-9E93-52975E212F6C

    41233DE4-8906-43E5-9E93-52975E212F6C

    Ecotec plus 615 noise
  3. 615

    615

  4. J

    Ideal Isar HE30 Combi Boiler - Replace Diverter Valve Head ?

    old post hijacked best to start a new post and not tag on to an old one. Gets confusing
  5. J

    No fill loop

    or maybe in the loft, near where the little cistern is / was
  6. J

    Where best to site boiler & flue - help appreciated

    not great to run it thru a ceiling above a bedroom - there are new regulations for flues-in-voids that you would need to think about. Inspection hatches would be required so the flue could be checked, Why not fit the new one in the kitchen
  7. J

    Y-Plan Fault

    not that one, this one - it's on the second page of Boiler & Central Heating FAQ's section - sorry, don't know how to do a link.... Boiler & Central Heating FAQ's section 17) MID POSITION VALVE EXPLANATION AND DIAGNOSTICS
  8. J

    Y-Plan Fault

    sorry, meant to say Boiler & Central Heating FAQ's section
  9. J

    Y-Plan Fault

    there is a great post in the FAQ's on Y plan fault finding, take a look... If you have a multimeter that would be helpful, if you are competent on system electrics
  10. J

    MM 7774 transformer

    great, thanks so much for the quick reply. John.
  11. J

    MM 7774 transformer

    Hi all, I'm competent with wiring but know nothing about transformers I have a micromark 7774 230V input / 12V AC output 65W max transformer that I need to replace with something similar - I have no idea what to buy. I have the usual sheds nearby. Screwfix, toolstation, wickes & B&Q...
  12. J

    New radiator added to system not getting hot

    did you cut into the 22mm flow/return pipes or the 15mm pipes that go into the existing rads ? did you turn on the rads valves both ends ? did you bleed both rads so they are full of water ? try to turn off all other rads, do both now get hot ? If so, probably needs a bit of balancing -...
  13. J

    Leaking combi boiler

    doesn't sound like there is a prv pipe fitted...............
  14. J

    Another Leaking Magnaclean !!!

    red valves on these always leak - get hold of the newer magnaclean black valves and fit them instead.
  15. J

    Is my boiler illegal?

    whoever told you it was "illegal" is in the wrong. As for is it safe.... can't say for sure as it has to pass certain tests - if you're not replacing it in the near future, why not get is serviced by a local RGI
  16. J

    Vaillant Turbomax 828E won't repressurize

    is the braided hose (filling loop) separate from your boiler ? If it is, you shouldn't be touching any valves on the boiler. Just the ones either side of the filling loop low pressure can stop the boiler working for dhw. If your talking about temperature issues, then that's a separate fault
  17. J

    DHW heat exchanger Worcester bosch 37 CDI - please help!:(

    usually I take out the plate from the back (towards the wall) - can be straightforward but can be a right pain if space is restricted
  18. J

    Flue bracket question - new regs?

    If that is your opinion of BG, then why would you sign up with them ? Anyway, It depends on the length of the flue
  19. J

    No drain valves on radiators?!?

    not all systems have drain off valves. Good practice to have them though. Maybe you should have stuck one in for next time