  1. F

    two way with two core

    I've heard that two way switches can be wiried using two core. Not that I want to do it, but has anyone got a diagram of how this is done? FG.
  2. F

    Fixed wiring test

    Would I also be able to do the CU main earth myself? I've installed CUs in pre-part-P days and never had any trouble with them (they have been inspected for PIRs).
  3. F

    Fixed wiring test

    I don't see the danger. The Water bonding is in 4mm, but is under cover all throught the run. Consumer Unit main earth is 10mm. I think that £217 is a bit much for that work.
  4. F

    Fixed wiring test

    Just had a house fail one of these for: Upgrade the main earth conductor to 16mm Upgrade the main equipotential bonding to the water I don't see why I need to do it seeing as both the bondings were up to regs when installed,, even if reg have changed since.
  5. F

    F'in builders

    They normaly advertise in the local press as well. They used to advertise in the London Gazette, but I'm not sure that it still runs.
  6. F

    Rewiring Hair Straightners

    You need to open the case were the wire goes in. Then prepare the long bit of wire you cut off in the same way as the existing wires. Take out the stump wire and fit the long bit. Or get someone who's done basic electrics to do it!
  7. F

    messy solder joint

    The old man and I have been trying to learn the dark arts of soldering copper tube and fittings. We can make a water-tight joint but it looks messy and the solder doesn't get all the way round the joint. Where are we going wrong?
  8. F

    Mount Bathroom Shaver Socket in Patress?

    Why? Isn't the point of shaver sockets that they have an isolating tranny and so don't need any additional (RCD) protection?
  9. F

    Adding an additional Circuit breaker

    Never installed one of those beacuse of the RCD/non-RCD issue.
  10. F

    Types of Board Questions

    :lol: It wasn't a very good one! British Railways Board National Coal Board Electricty Board Gas Board See, all different types of board.
  11. F

    Adding an additional Circuit breaker

    Have you got a split-load board? Ovens are normally on the non-RCD side of things as they can have quite a high earth leakage during normal use. Take a full picture of the board. What size cable are you planning on using for your oven? Have you planned for a DP isolator (at least 45A)?
  12. F

    Stupid mistake with electric lawnmower

    When I was a kid I was replacing a socket with the old man. We had got it off the wall and yours truly was just uncrewing the wires when ouch! We had forgotton to turn of the circuit MCB :oops:
  13. F

    Gas purge required after property left empty

    They must surely (attempt to) equaliase beacuse of Brownian motion of the molecules. Take the leaking pipe as being a semi-permeable membrane, and you can see that there will be a diffusion of gas out and air in.
  14. F

    Gas purge required after property left empty

    Only for complete combustion to CO2 + H2O. If there was less air the gas (methane) could still burn, but incompletely leading to the formation of CO. I think what is being asked is what is the minimum % oxygen required in a gas/air mixture for there to be any combustion at all, however...
  15. F

    Picture of the week!™

    That bathroom is cleaner than anything I ever had as a student :lol: :lol:
  16. F

    Gas purge required after property left empty

    Ah! I see what you are saying. I was confused with people talking about 100% gas, which as you have clarified refers to the gas comming out of the jet rather than the combustion mixture (which cannot be 100% gas for it to burn). I've no idea what the ratio of gas to air would have to be for...
  17. F

    Gas purge required after property left empty

    If it is 'in air' then it cannot be 100% gas by definition as there is air in there! You couldn't light a match in 100% gas as there would be no oxygen for it to burn!
  18. F

    shaver point

    normaly the feed is taken from a lighting circuit.
  19. F

    New meter cupboard

    Ask them to remove the enclosure and bulid a new one around the CU and meter.
  20. F

    Small businesses - Beware of scam.

    A well known scam. Other tragets include a diary for the police or ambulance or things involving hospitals. These scousers are well known for it.