Search results

  1. A

    Citroen Saxo R reg side lights not working

    Ive got a R eg 1.4 citroen Saxo which has failed its mot due to the side lights not working . At the same time the dash board lights stopped operating as well as the light warning buzzer went silent . I think they are all related ,but am only concerned about the side lights not working ...
  2. A

    Concrete lintel repair (need advice)

    Thank you for your reply . i have set about making a wooden support in the shape of the lintel . This will help it form the correct shape while it settles (mixture of 4/1 of sharp sand and concrete . Will seal the finished area and then paint . I have already removed all the loose concrete...
  3. A

    Concrete lintel repair (need advice)

    Ive got a concrete lintel that has due weather rotted away from the main structure Pics below : How do i go about repairing it . I guess treat the rust ,seal the concrete and fill with concrete or concrete gravel mix .Then seal and paint . Advice on how to do the above and with which...
  4. A

    Require practicle experience in inspection and testing

    Im a JIB registered electrician who requires some practicle help . Ive just completed my 2391 in inspection and testing course . I was wondering if theres anyone on this forum who could offer me some practicle experience around the W.Midlands area in inspection and testing . Im not looking...
  5. A

    Baxi 51/5 (no heating or hot water)

    Baxi warranty ran out in April , & its up to its old tricks again .
  6. A

    Baxi 51/5 (no heating or hot water)

    The boiler fired up this morning after i removed the thermcouple was removed from the front of the boiler . This was refitted after 15 mins & the boiler did not lockout. I have switched the CH & hot water on & off over a couple of hours & everthing is working fine for the moment . What...
  7. A

    Baxi 51/5 (no heating or hot water)

    I did not tighten the screw , just noted that it was screwed in to what seems to be the max pressure position according to the info supplied (thought the info might help someone deduce my problem). At no point did i claim to know how to set the gas pressure or was a expert in boiler...
  8. A

    Baxi 51/5 (no heating or hot water)

    The fire front is Baxi Bermuda LFE5 super . Serial numberLYK034800087AP.
  9. A

    Baxi 51/5 (no heating or hot water)

    Yes that is correct . Ive been in this house for 18 months , the original owner said the central heating is recently fitted . I dont think it is personally (maybe 5yrs old or more). Noted that the gas pressure screw seems to be all the way in (clockwise in)
  10. A

    Baxi 51/5 (no heating or hot water)

    What should i be looking to pay someone to the adjustments necessary ?? What does it look like to be the likely fault ?? Ive been qouted over the phone by Baxi themselves wait for it....... £279 .Thats over the phone ,without any inspection ,
  11. A

    Baxi 51/5 (no heating or hot water)

    baxpoti said: Make further checks for leaks Check the burner setting pressure, adjusting if necessary, this has to be done while the LED is illuminated. This is done by removing the governor cover screw and adjusting the governor in either direction as required:- clockwise to increase...
  12. A

    Baxi 51/5 (no heating or hot water)

    When you first switch on the heating ,the system will ignite & run for approx 2.5mins & go to lockout . The main led will go to red indicating lockout , but the smaller amber led will flash at aproximately once every 6 secs. Hope this helps .
  13. A

    Baxi 51/5 (no heating or hot water)

    namsag:Cleaned what i assume is the pipe marked 1 in yellow .(if incorrect indicate which is the correct one please . gas4you :Checked the pump & it spinning & filling the tank . Got a orange led flashing on the timer board (marked 1 in green which is next to a thermocouple connection...
  14. A

    Baxi 51/5 (no heating or hot water)

    Im a total novice to back boiler systems.What i need is a step by step guide of what to check . Im a electrician by trade so should be able to follow instructions (hopefully).
  15. A

    Baxi 51/5 (no heating or hot water)

    Removed the front heater from the boiler system . The flue looks clear . The system calls for ignition & lights up for between 10-240 secs then gos to the red led state . Something is causing it to lock out , but unsure what ?? Is it helpful if i try the water & heating seperatley & see...
  16. A

    Baxi 51/5 (no heating or hot water)

    When you reset the system ,the timer unit ignites (THE LED GOES FROM AMBER TO GREEN)& the boiler switches on for approx 2.5 minites & then gos to lock out condition . Can anybody help me diagnose the fault ,to why its locking out ??
Back