ufh

  1. Ouch77

    Polypropylene membrane tape?

    I'm preparing an area for wet UFH system. The insulation is down, and I'm considering laying a 'decoupling membrane' by Laminon (which helpfully has a grid printed on it to align the pipework to) prior to pipe fitting and screeding. It's sold in 1.2m wide rolls, so will have joints - I...
  2. C

    Boiler overheating with UFH

    Good afernoon, I recenlty extended the house and added a small area of UFH to the main heating (radiators) system. Since the installation, the boiler randomly overheat and shut down. This only happens when the UFH starts, mainly in the mornings and especially if it starts at the same time as...
  3. fatmcgav

    Wunda Rapid Response in new kitchen

    Hey there We're mid way through finishing up the mess that our builders left us with for our extension. I'm currently considering installing a Wunda Rapid response 20mm wet ufh system instead of rads. One potential challenge is that ideally I need to get the kitchen fitted ASAP, as it's sat...
  4. Hayk

    Can sensoCOMFORT VRC 720F run my UFH pump?

    Hey guys. I am in a bit of a pickle, mostly because what I want is not considered "conventional" in the country I live in, so I have a hard time getting the advice I need. I have a " VAILLANT ecoTEC plus VUW 26CS/1-5, 21 kW" boiler + "sensoCOMFORT VRC 720F" combo fitted to work with my UFH of a...
  5. W

    Draining all water from UFH pipes?

    Winter is approaching and our barn conversion is without a boiler installed, and no mains electricity on the horizon, therefore, no way of heating the place. The ground floor screed has been poured, with the UFH pipes (pert-al-pex) filled and under pressure. My concern is the internal room...
  6. A

    Underfloor heating RCD tripping

    Hi I have a Heatmiser UFH on two floors. One of the floors - UFH8 - RCD is tripping. First I just replaced the 5A fuse in Heatmiser UHF8- did not work - as it tripped immediately. I removed the power from Grundfos UMP3 - and placed the 5A fuse and again it tripped. I removed all the neutral...
  7. B

    Veissmann Vitodens 111 failing to send hot water to Underfloor Heating

    Can anyone help? We installed a brand new Veissman Vitodens 111 and underfloor heating system (Ambiente Manifold, Grundfos ump3 auto pump, and Heatmiser Controls) 18 months ago. We've had no issues at the tail end of winter 2022 and all of winter 2023; but when things switched on this week its...
  8. C

    Combi Boiler anti-cycling lockout: The technical/engineering reason for it, is what?

    TLDR OK, this is not so dozy a question - and the background is below for people who want to know why I am asking this, but bottom line: What is the technical reason for anti-cycling lockouts? Does constant firing use too much gas, wear something out - what? Put it another way: If there was...
  9. T

    Underfloor heating on suspended floor

    I'm planning to fit a wet system underfloor heating on my ground floor. So need some advice please: The floor is timber suspended as shown below. The height of the gap below the joists is about 500mm. The joists themselves are 4'x2' (100mmx50mm). I plan to: - use battens on either side of the...
  10. U

    Heatmiser UH4 - Wiring Zone Valve / Manifold Pump

    Hi everyone, hope you are well. I am looking at installing the UH4 for our 2 zone wet UFH system. According to the diagrams, there is only one input labeled "MANIFOLD PUMP OR VALVE" with Live, N and earth connections. I am still in two minds whether we need a 2 port zone valve or not as the...
  11. G

    Underfloor heating power

    Hi everyone, we're thinking of getting some works done in our loft and have a chance to get underfloor heating installed. I have been reading around on this forum and the web and would like some advice before deciding on next steps. We want to get 3 x underfloor heating mats (UFH) across 3...
  12. E

    Glued Flooring over screed and UFH

    We are in the middle of a small kitchen extension and have installed wet UFH over insulation and screed which was laid on 13th December. We have engineered wood flooring to be installed on top (glue down). Our builder is now saying because the flooring is glue down it will need more drying time...
  13. alex0291

    Minimum space required for UFH (Ed.)

    Good Evening Everyone, This is officially my first post here, and even tho i made a bit of research on the webiste before to post this, i was not able to find the answer to my question (if someone already replied to something similar, i do apologise in advance!) I'm about to purchase a...
  14. T

    Luke warm radiators - on Rad + UFH System

    Our house has a heating system identical to the one pictured. System boiler with unvented HW cylinder, upstairs radiators (12 of them) and about 100 square meters of UFH. All separated by individual 2 port valves. We've recently been renovating the far end of the house (and far end of the...
  15. A

    Multizone system and OpenTherm, mixing radiators and underfloor heating

    I’m in the process of acquiring a new boiler due to the conversion of my loft and the installation of a mechanical ventilation and heat recovery system. I’ve recently discovered that Google Nest is unable to handle multi-zone systems and reverts to a simple on/off thermostat. My preference would...
  16. Auric

    Is this quote for an extra UFH manifold right?

    Hi all I'm having a kitchen extension built and getting UFH installed - the quote for that is £2900, which sounds about right to me. Eventually, I plan to install UFH in the rest of the house myself, so I've asked for a quote for putting a four port manifold on the first floor too as part of...
  17. M

    warmafloor UFH replacement or parts

    has anyone attempted a "diy" to replace the flow meters and valve pins on a warmafloor UFH manifold ? also how easy is it to just replace the whole thing as I'm seeing manifolds for under £200 and wondering if its worth buying parts or just replace the whole thing but I'm not sure how straight...
  18. B

    UFH - Free Design Software ?

    I have an existing 20+ year old UFH install but don’t have the original designs or design Flow Rates per circuit. I have measured up the rooms and using thermal camera can see the circuit spacing is approx 150mm in Spiral layout. I’ve flushed all the loops and cleaned all the flow meters, but...
  19. A

    Underfloor heating on new and existing space

    My partner and I just started building a 4mx7m rear extension. We plan to knock two walls down so the extension is part of a large open plan space along with the current kitchen/dining room (also 4mx7m). We've already decided to install wet UFH on the new part, but we are struggling to decide...
  20. kminbuildinghell

    Floor disaster

    Wondering if anyone could shine some light om my flooring? Ive got amtico spacia, ontop of an electrical ufh system which has been set into a screed. Its been done by a professional but after 2 weeks the floor started bubbling, and the mat that the cables sit in has buckled in several areas of...
Back