DIY Hive heating only installation

Joined
10 Oct 2019
Messages
9
Reaction score
0
Country
United Kingdom
Ok so I have read a lot of posts/threads watch the video ! And feel more the wiser for it, but not found that exact setup I have, so after a bit of advice, I have a 3 bed detached house with a logic es35 combi boiler running 2 zones , one upstairs and one down stairs, using Honeywell cm707 Thermostates , the combi is downstairs with nothing around it I can see I need to get into , upstairs in a cupboard is little electrical box next to 2 valves labelled upstairs and down stairs
See attach photos

im guessing I don’t need to do anything with the back of the thermostats themselves ?, and the wiring behind them goes to that junction box in the upstairs cupboard?
so I’m guessing I just need to disconnect the stats, and that’s where the receiver needs to go?

So I just need to work out what all the other wires are?

There is some writing on the back box but not sure it relates to much

any help/advice appreciated
 

Attachments

  • F7F75433-B7FB-4D75-840A-01667646A585.jpeg
    F7F75433-B7FB-4D75-840A-01667646A585.jpeg
    162.2 KB · Views: 230
  • BE57F24F-6726-4FE2-8C48-C3D194F0C18F.jpeg
    BE57F24F-6726-4FE2-8C48-C3D194F0C18F.jpeg
    126.4 KB · Views: 194
  • 6EF790CC-344F-47B3-8749-D5981EE1DFA1.jpeg
    6EF790CC-344F-47B3-8749-D5981EE1DFA1.jpeg
    213 KB · Views: 173
  • 666AF308-72EE-4ED0-9101-C1E2DAD467E2.jpeg
    666AF308-72EE-4ED0-9101-C1E2DAD467E2.jpeg
    194.6 KB · Views: 185
  • D7900A65-8BFF-4988-9835-3922317CE6D1.jpeg
    D7900A65-8BFF-4988-9835-3922317CE6D1.jpeg
    164.6 KB · Views: 164
  • 96CB2631-CF4F-493A-BB9F-329F985D4DB8.jpeg
    96CB2631-CF4F-493A-BB9F-329F985D4DB8.jpeg
    278.1 KB · Views: 194
  • 292EC552-E5CA-4B32-98C5-1798DAD3E7FB.jpeg
    292EC552-E5CA-4B32-98C5-1798DAD3E7FB.jpeg
    108.5 KB · Views: 184
Sponsored Links
Your existing Honeywell thermostats are battery operated so don't have a 230V supply connected to them.

You are right in that the existing wires in each of the Honeywell A & B terminals could be connected to two Hive receivers (single channel version) Use terminals (1) Common and (3) Heating on. It doesn't matter which way around they go it's just a switch.

Then you will need to run a new 230V supply to both of the new Hive receivers N & L terminals to power them. This should come via the same 3A fused connection unit, that supplies the boiler.
 
Last edited:
Your existing Honeywell thermostats are battery operated so don't have a 230V supply connected to them.

You are right in that the existing wires in each of the Honeywell A & B terminals could be connected to two Hive receivers (single channel version) Use terminals (1) Common and (3) Heating on. It doesn't matter which way around they go it's just a switch.

Then you will need to run a new 230V supply to both of the new Hive receivers N & L terminals to power them. This should come via the same 3A fused connection unit, that supplies the boiler.

oh ok sounds straight forward enough, apart from the 230v , shouldn’t there be one in that box I. The cupboard ? It looks like there is, the writing after looking more carefully is Earth Live Neutral !
I got no way of running another 230v supply to that cupboard
 