Hi everyone

I am new to this forum. I posted a question and had no idea it was a private message. Hopefully, this is public? If it is still private, please let me know.

I have added a MC1MINI-WE magnetic contact for shed to the Enforcer. I have added it to area B and set it to Intruder [6]. Everything was allocated to area A. I changed front door contact to area A and B, which is the final exit [7].

On keyfob, buttons I and II set and unset area B, which is the shed.

Problem is to set the shed, we have to open and close the front door. Also after setting, anytime we open the front door, we have to unset and set the shed again.

How do you set the parameters to keep the shed separate from front door? If I allocate front door to area A only, then shed does not set. Any ideas please?
 
Sponsored Links
What are you trying to achieve?

Are you wanting the shed to be set along with the house or independently to the house?

Post a list of your inputs and the settings / zones for each

I and II on the fob shouldn’t set B either. You’ve changed the defaults it would seem.
 
Ignore the above I think I’ve now understood what your looking to do…

Remove the door from Area B and change Area B’s exit mode in the engineers menu to timed
 
Hi everyone

I am new to this forum. I have edited my post to make it clearer (hopefully). Any help is appreciated.

I have a Pyronix Enforcer with;

2 PIRs set to Intruder [6]

1 magnetic contact for front door set to Final Exit [7]

All 3 allocated to area A.

I have added (or trying to add) a MC1MINI-WE magnetic contact for shed. I have set it to Intruder [6] and added it to area B. The aim is to have it set at all times, except when we need to access the shed.

I allocated the front door contact to area A and B.

I have created a code to set and unset area B only, which is the shed. Also, changed the codes of the family to area A and B.

Problem is, in order to set the shed, we have to open and close the front door. Also, after setting, anytime we open the front door, we have to unset and set the shed again.

How is it possible to set the shed at all times, except when we want to access it? How do you set the parameters to keep the shed separate from front door? If I allocate front door to area A only, then shed does not set. Any ideas please?
 
Sponsored Links
Under system options do you have level set, set to yes or no. It needs to be no if you potentially want to set multiple areas at one time
 
Under SYSTEM OPTIONS I have

Site Options

System displays

Exit Modes

I do not have level set.
 
Level set is in site options
Site options press yes
Press yes 7 times,display should show
Use level set
Use arrow to toggle between yes or no the yes to confirm
Press on back to site options
Hope this helps
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Sponsored Links
Back
Top