Recent content by casademont

  1. C

    What is best practice to connect a 3/4" female-to-male thread

    I am fitting a 15mm x 3/4'' Compression Female Iron Coupling adapter: The 15mm compression end is easy, but what's the best practice for fitting the 3/4" female-to-male thread? There is no compression feature, just interlocking threads. Should I use a 3/4" washer? Just wrap with a lot of...
  2. C

    Is gas PTFE tape safe for use on potable water sources?

    I have some of this tape left over and want to use it on a drinking water pipe: It only says "for all common gases and liquids" but not explicitly "for potable water" as the usual white stuff does. Is it safe? Just trying to save myself a trip to the shop!
  3. C

    PVA, SBR or BondIt?

    I have a brick wall that I intend to install a bath against with a fixed shower head: I'll use either tile backer board (insulation + cement layer) or hardibacker with a tanking kit; attaching via dot and dab (plasterboard adhesive) and screws + washers to hold it in. However, what's the...
  4. C

    6mm or 12mm (or thicker) MDF back panel for wardrobe?

    Thanks, my local yard only has 4mm ply - would this be strong enough? Also what is it like to paint? Would it match the MDF in terms of general aesthetic if it is all white or will the ply have more noticeable grains?
  5. C

    6mm or 12mm (or thicker) MDF back panel for wardrobe?

    I'm building some fitted wardrobes out of MDF. Would you recommend a 6mm or 12mm back panel for each unit? I'd prefer 6mm to save on space and cost but wondering if that would cause any issues. It's going up against a stud wall if that makes any difference. First time builder so thanks for...
  6. C

    Do I need to prime recently painted doors again?

    I painted some doors in Dulux Quick Dry Satinwood (water based) about 12 months ago. Prepped well (sanding, primer, etc) and they came up really nice. I did 1 coat acrylic primer, 2 coats top. Since then we had some unexpected building work done, and they are all dirty enough to require...
  7. C

    Can you have a socket on a 20A ring?

    I have a new house and realise there is a socket on the ring to the boiler (20A). Is this a problem / do I need to have it moved to a 16A fuse?
  8. C

    Does anyone have experience with an RTL valve?

    I want to put underfloor heating in a small ensuite (just 3.5 sqm). Having researched options (electric vs. wet), I found what seems like a good solution in using an RTL valve (return temperature limiter; https://www.floorheating-direct.co.uk/product/rtl-valve/). This solution just connects...
  9. C

    What happens when a transformer is below the power consumption of an LED?

    I have installed a run of 5m LED strip lighting, rated at 24w (300 x SMD 3528 leds for those interested). However, I realise I made a mistake and connected it to a 12V DC transformer rated at 12W. The lights are in the kitchen and have worked fine without any noticeable problems. What risks...
  10. C

    Recommended spacing for cabinet doors

    @JobAndKnock Thanks, they are in-frame/inset doors built with 22mm MDF. Like this, but opening together in pairs and with concealed blum soft close hinges:
  11. C

    When is a deflection head required in a stud wall?

    I am researching putting a non-load bearing partition stud wall in a loft space (pitched roof construction). I have read that if I were to specify a gypframe studwall then a deflection head is required (http://www.british-gypsum.com/technical-advice/faqs/020-what-is-a-deflection-head). However...
  12. C

    Recommended spacing for cabinet doors

    Thanks, I intend to use concealed blum soft close cabinet hinges. Would 2mm around the frame and 4mm between where the doors meet work?
  13. C

    Recommended spacing for cabinet doors

    I am building a cabinet (basic MDF stuff), what clearance/spacing would you recommend for the doors on the top, bottom and sides? Is 2mm all around enough or do people normally give a bit more room?
  14. C

    Adequate ventilation in a cold loft

    I have a cold loft in a pitched roof. Insulation is over the ceiling not under the rafters. I want to put 9mm plasterboard up under the rafters for aesthetics, I won't insulate between the rafters (100mm deep) as there is already insulation over the ceiling joists. If I do this, do I risk...
  15. C

    What certificate should a flueless gas fire have?

    I've just had my flueless gas fire replaced by a gas safe engineer. However I forgot to ask for the certificate - what specifically should I be asking for when I ring them? Reading here...