Recent content by Ethel

  1. E

    chimney leadwork

    House is 75 years old. BCO just happened to notice it prob trying to justify the fee of £135 for a five min visit. Quote included full replacement.
  2. E

    chimney leadwork

    I have had my roof retiled and the building inspector noticed that the leadwork at front bottom of chimney was the old leadwork. The stepped sides had been redone. Is it normal practice to leave old leadwork that is many years old. Thanks guys
  3. E

    wet insulation

    The roofer said it gets wet when it touches something and they put tiles on in rain. Thanks guys for your replies.
  4. E

    wet insulation

    Advice please Is this material waterproof? Ridge tiles cant be put on as too cold. Could rain come through.
  5. E

    wet insulation

    my loft insulation is wet as the breathable membrane the roofer left uncovered for two days let rain in. Should it be replaced or will it dry out. marg
  6. E

    crimping joint

    He did'nt use a soldering iron - just twisted the core wires together and slipped black sleeve over (small tube with lengthwise cut so it could fit over) then crimped using pliers and put insulating tape over it. Whole joint is behind metal hood touching metal. Beginning to think its not safe...
  7. E

    crimping joint

    Sorry i dont have a photo - joint obscured by new hooood fitting - wonder wetther black sleeves correct
  8. E

    crimping joint

    sorry not seen what tool he used- obiovisble not a ratchet tool with coloured joints
  9. E

    crimping joint

    This is not yeollow or blue but blacck sleeves put up after wire joined by hand- is this ok
  10. E

    crimping joint

    Please can you advise me if a crimping joint is safe without heat shrinkink when it is in touch with metal
  11. E

    Replacing junction box with crimped joint

    When replacing my old cooker hood the fitter (not an electrician) removed the junction box connecting the hood cable to the mains replacing it with a crimped joint which he tucked into hole in wall where JB was and fitted hood unit over it. The connectors used were small black sleeves fitted...
  12. E

    Filling 4 inch hole in cavity wall

    My new extractor hood won't fit with existing hole so I have to have new hole drilled & existing one filled in. How best to do it to ensure concrete does'nt fall into cavity & cause probs? The walls are block built. Thanks
  13. E

    electrics

    I have had a new hob and cooker fitted and both required junction boxes to fit the cables. The boxes were not attached to the wall but left hanging loose - is this safe? The hob box hangs loose in a cupboard and could be knocked about by ordinary use of cupboard to store things.
  14. E

    MCBs

    How do I change old fuses to MCBs - is it easy?