    Cold water higher pressure than the hot water?

    Sounds like the whole house pump is the way to go no point fitting a pressure reducing valve then adding a pump for the shower might as well just pump the whole lot with a £300 pump.
  2. N

    Cold water higher pressure than the hot water?

    they were just options and since when did a whole house system pump cost £5000, your clearly a plumber.
  3. N

    Cold water higher pressure than the hot water?

    Obviously there were no replies before I started typing, but I still think these other options are valid and should do a better job, but a pressure reducing valve is certainly cheaper! especially if he wants the power shower anyway
  4. N

    Cold water higher pressure than the hot water?

    Assuming it is gravity hot and mains cold (which sounds very likely, i.e. tank in loft), then really you would need a one hole tap with a dual flow spout (not mixed in tap) or a low pressure mixer tap with non return valves on hot and cold feed. Most taps, unless they specifically say so, are...
  5. N

    unvented cylinder or shower pump?

    Hi Powell30 The more I research the more it looks like you cannot get someone to sign off the work but I have just spoken to someone else in building control explained my doubts he conferred with his colleagues (including the Principal Building Control Surveyor) and agreed that I can do it...
  6. N

    unvented cylinder or shower pump?

    I understand the concept of an unvented system very well, as you will see from my first post (I put the bit in brackets just in case someone else misunderstood) "Is it OK to pump the entire hot and cold system (only gravity fed side obviously)" i.e. get the same from a pump (the whole...
  7. N

    unvented cylinder or shower pump?

    Thanks dangermouse46 are you 100% sure that the building control guy was wrong? I was quite looking forward to a new challenge............... Perfect example of how dangerous pressure vessels can be whilst writing this my wife has just tried to hard boil an egg in the microwave, what a nob...
  8. N

    unvented cylinder or shower pump?

    Thanks for the quick reply Lagunaglen It has been 4-4.5 Bar for the last couple of weeks and >50litres/minute so should be plenty, I just want to pump the gravity fed cold not mains pressure. I had to re fit/configure the current cylinder, and all of its controls mostly due to the terrible...
  9. N

    unvented cylinder or shower pump?

    I want more pressure for 2 showers and the kitchen sink. I was thinking of replacing the gravity fed cylinder with an unvented cylinder to get mains pressure but because of awkward discharge positioning and the £700 cost (fitting myself, including building control checks) I have been thinking it...
  10. N

    Do I need to replace the finish skim for tiling

    Hi I have just removed my kitchen tiles and the 3/2mm skim coat came with most of them so I removed the rest (leaving some sort of brown plaster/screed behind). I am going to tile again but having never tiled or plastered before I can't decide whether it is worth putting a finish layer of...
  11. N

    No insert in MPDE pipe at stop tap

    OK thanks Guys consider it done! Probably would have done it anyway but now I have a touch of fear to encourage me to do it sooner Fingers crossed it doesn't flood the solid oak floor before I get the chance to fix it.
  12. N

    No insert in MPDE pipe at stop tap

    I live in Gloucester and used the time we spent without water (after the flood?) to replace a stuck stop tap and some shoddy pipework nearby as the stop tap chamber in the road was blocked and it seemed like a good opportunity. Must admit I was a bit nervous I would return from work and find the...
  13. N

    Very noisy (gargling, glogging and gurgling) hot water loop

    Thanks for your help Gas4you, will order a Myson aerjec tomorrow with any luck may then get a full nights sleep for once.
  14. N

    Very noisy (gargling, glogging and gurgling) hot water loop

    Right I'm mostly with you now but could you just clear up the position (as far as flow) of the Pump: Order in Height: 1. Aerjec (highest) 2. Pump 3. 3 port valve (lowest) Order in flow from boiler: A 1. Aerjec (first) 2. Pump 3. 3 port valve (last) B 1. Pump (first) 2...
  15. N

    Very noisy (gargling, glogging and gurgling) hot water loop

    I thought I had it how you meant, the vent take off is higher than the 3 port valve and a bleed point is added to the H/W feed. Is this how you meant? Do you mean the only difference to how you would have it is that I should have a Myson aerjec where the vent take off is (I do plan to do that...