Search results

  1. K

    Grrundfos Pump Intermittent Failure & Very noisy

    This is the sound I get. You can hear the sound by scrolling forward to 1min 2secs. This video is not of my pump though the photos posted are. Read more: https://www.diynot.com/diy/threads/grrundfos-pump-intermittent-failure-very-noisy.504492/#ixzz5IrYyQGmP
  2. K

    Grrundfos Pump Intermittent Failure & Very noisy

    Background I have a Grant Vortex 36E Oil fired boiler. Two Grundfos pumps inside; one for the rads & one for the hot water. The Problem The pump on the hot water circuit is making a howling noise when I run hot water. But not always. The hot water pump has, and as far as I know, always has been...
  3. K

    Garage uprights in UPVC, or something else. Supplier?

    Thats a good idea. I saw some upvc square pipe in SIG Plastics, and though about it, but didn't think to put the fence post inside. I'm going to chop out the rotten base bits this weekend and splice new timber in and then clad with the upvc. Going to get loads of silicone under the base of the...
  4. K

    Garage uprights in UPVC, or something else. Supplier?

    Thanks, I went by GAP, Eurocell & SIG Plastics and after asking in those places got the various angles and flat strips. Cheers
  5. K

    Garage uprights in UPVC, or something else. Supplier?

    Garage doors are framed with timber. Base of timber has rotted. Wish to replace with white UPVC or other that requires no maintenaince, so never have to re-visit, or re-paint. Sizes needed are: 70mm x 70 mm x 2300mm (size is like a solid fence post except perhaps longer. Does not have to be...
  6. K

    Anyone know supplier for galvanised flashing 40mm x 40mm x 1mm x 2200mm ?

    I used a local sheet metal company. I forgot I knew them, so long since i've been in there. They cut quality stainless and folded it. Quick cheap and friendly service.
  7. K

    Anyone know supplier for galvanised flashing 40mm x 40mm x 1mm x 2200mm ?

    Need galvanised flashing for bottom of garage door. Top picture shows what's needed. Bottom picture shows what was there and has been taken off. Taken off is 'Dexian 140' x 2200mm, but it's rotted. I've phoned every local supplier I can think of looking for this. I was helpfully told by one that...
  8. K

    Cistern Fluidmaster PRO550UK push button does not stop water flowing after flush

    I have the Fluidmaster PRO550UK fitted to a cistern in the house. https://www.amazon.co.uk/Fluidmaster-PRO550UK-Front-Mounted-Flush/dp/B0060X5Q0A/ref=pd_lpo_vtph_60_bs_t_1?_encoding=UTF8&refRID=X9T0EAWVS9C7588BV1R7&th=1 Generally it works exceptionally well, but occasionally when the large...
  9. K

    Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen

    Thanks. I put some info for benchmark below "To maintain the boiler guarantee it is essential that the boiler is serviced annually by a Gas Safe registered engineer who has been trained on the boiler installed. The service details should be recorded on the Benchmark Service IntervalRecord and...
  10. K

    Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen

    With the number of ebay exchange services listed in the above ebay link, for the PCB, I'll bet there are parts on there that fail more than others, and that there may be one part that generally causes failure when the board goes? (most folks could sort that out with a few spare parts, a multi...
  11. K

    Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen

    Also discovered boiler is under warranty. She was not that fussed about proof of servicing :) It gets the CORGI cert every year. The same thing ? (I ask the service engineer to do what's necessary when he comes annually) Very helpful all together. ######### Ideal Customer Service CONTACTS...
  12. K

    Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen

    Thanks for your help guys Phoned Ideal; was difficult getting through but got there eventually. Spoke with Ideal engineer. He said is there is no commonly known part on the PCB that fails. He suggested re-cycling the power at the wall. He said it can be an incoming power supply problem. I...
  13. K

    Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen

    Have a Ideal Logic 30 (Combi Boiler) with "PCB Fault" on screen (photo below). No hot water for anything. Manual gives no indication. Photo of serial number below. Anyone ideas? I gather the "1304" means it was manufactured in 2013 on the 4th week of the year.
  14. K

    Where to get brass connector 1/2in male to 1/4in male ?

    Have done a few searchs including this one here. Anyone; where to get metal (brass?) connector marked in picture 'NEEDED'? Thanks
  15. K

    Expansion vessel kit male connector appears to be very slightly less than 15mm

    Hi, I just fitted a wall mounted 25L expansion vessel to the heating circuit of an oil fired combi-boiler. The machined 15mm male inlet connector on the expansion vessel kit is connected to a female 15mm compression nut with olive and plenty of PTFE tape. The female compression join comes from...
  16. K

    drip from radiator fitting

    Just tighter then?
  17. K

    drip from radiator fitting

    Hi Photos show there is no slack on the compression fitting to allow me to get any ptfe tape on. Because it's not possible to move the compression nut back so that it exposes the olive. What can I do?
  18. K

    Kitchen cabinet hinge off, whats the best way to repair ?

    John, thanks. Good ideas. Door had definitely been opened way too far, pulling out the hinge. May have been exacerbated by the door being closed against the large toblerone shown, putting a leveraging moment on the top hinge. Bottom hinge screw seating is ok. The plasterwork had evidence of the...
  19. K

    Kitchen cabinet hinge off, whats the best way to repair ?

    They'd snapped the door back. Original screw (small) and thick screw used shown. Thick screw did the job very securely. Thick screws were unused part of fire door closer pack. Great screws
Back