Search results

  1. P

    Vaillant Boiler No Hot Water

    common fault with these.The diverter valve is faulty.This can be done by yourself as no gas work .Isolate boiler drain down boiler remove pump,undo nuts to plate to plate a few nuts on diverter.Make sure you use new o rings and washers with some silicone grease.
  2. P

    problems with a Britony Combi SE

    i would say pcb have loads of these on our area and this is a common fault
  3. P

    Chaffoteaux & Maury Combination boiler

    Pcb have the same trouble with the se changed loads
  4. P

    fujitsu esprimo laptop

    Hi i wonder if any one can help.This laptop is about 2 months old but has just started to run very slowly.We had warnings to say there were problems but all the fixes it says it does will not change the speed.Have tried to restore setting but windows wont allow.Is there a way to restore it back...
  5. P

    new brakes,spongy pedal

    the brakes were fine before i changed pads
  6. P

    new brakes,spongy pedal

    96,000 on s reg
  7. P

    new brakes,spongy pedal

    hi i have just changed front and rear pads and parking brake shoes on my ford explorer.The pedal feels spongy, not all the time every now and then.The fluid was not very low so i dont think air has got in.If i push pedal and then release and push pedal again straight away the pedal is...
  8. P

    biasi 28 compact

    thanks for the reply the boiler runs at full and does not modulate i did not try burner pressue well do that monday .what should this be for riva 28 compact he.I thought 41c was not to bad but they want more :? thanks peter
  9. P

    biasi 28 compact

    Hi just been to a job" Hot water not as hot as before"Have tried to explain to customer that when the the boier was installed in the summer the temp of the cold main was alot warmer than now in winter :roll: Coukd some one please tell me what the temp rise for this boiler should be, i am getting...
  10. P

    romeo gas fire

    Hi could any one direct me to find MI for this fire. It is a Romeo 16 inch made by Fell fires of Ashton , Newcastle thanks peter
  11. P

    saunier duval 623

    hi ollski what is the best way to test,is one side of multi go to earth and other to terminal or a prope to each terminal.How old are these boilers thanks peter
  12. P

    saunier duval 623

    hi have this boiler no hot water or heating.the pilot is alight and fan running ,pressure is 1.5 bar.Pressure switch is making switch ,could yo please advise how to test to see if gas valve has power going to it.There are two wires going to the solnoid on gas valve ,could any one help with any...
  13. P

    ariston micro genus

    found what ariston call it "MAIN CIRCUIT FLOW SWITCH" thanks for your time tony. peter
  14. P

    ariston micro genus

    hi tony thanks for the quick reply.I removed the two grey wires from the switch and the heating did go off.Do you happen to know the proper name for this part thanks peter
  15. P

    ariston micro genus

    hi have this problem with this boiler.The central heating fires up on this combi even when no demand for heat.I have moved some cables on the flow switch,i think thats what the part is,the problem stopped for a short period.Just wondered if any one could tell me if this part could cause this...
  16. P

    basin pedestal

    hi does any one know if ideal standard make various height pedestals.Problem is exsisting basin has been tiled around and client has no spare tiles,the exsisting basin and ped was lower than the new one.Just wondered has any one have any ideas.Pedestal is white.Thanks peter
  17. P

    myson midas combi

    thanks for your help :D :D
  18. P

    myson midas combi

    I think thats what has happened every time they have had a eng out.The boilet has not been touched for18 years not even a service.The owners could not understand why the boiler was faulty they kept sying things dont last as they used to :roll: do these have some kind of flow switch that turns...
  19. P

    myson midas combi

    hi just after some help if possible.Was called to this job today with no hot water.The boiler looks like something from the dark ages.I tried heating that is fine but no hot water, the pump for the dhw does not run.There are two pumps heating one runs fine.Could any one give any help on this one...
Back