    ATS path faullt no ATS available -Texecom 48 and Com300 card

    Sorry - the panel is a texecom 48 Premier - less than 6 months - the com 300 is "new" but could be old stock? it is the 10 pin type
  2. SgtWilson1

    ATS path faullt no ATS available -Texecom 48 and Com300 card

    Hmm, Hi Sparkymarka, by you question I am wondering if I have bought the wrong thing.... I want to use it as a dialer to alert me by telphone call if alarm triggers - is it the correct tool for that should I use something else?
  3. SgtWilson1

    ATS path faullt no ATS available -Texecom 48 and Com300 card

    Hi all - can anyone advise please. I have installed a Com 300 (CTR21 Communicator PN CEA-001) onto The Texecom 48 Panel. Using Wintex I have: In "Options" Tab enabled the communicator - tick dial all numbers - tick In Tab "ARCs" I have enterd the numbers I want to dial In...
  4. SgtWilson1

    Setting Areas Texecom 48

    You've done it again Mark! your knowledge of this panel seems endless, thanks very much for your help. Problem now resolved.
  5. SgtWilson1

    Setting Areas Texecom 48

    I’m struggling with the subject setup. For overview I have 9 zones set as Area A (House). 1 zone (currently) set as Area B Garage. 3 Keypads all set with Area A & B ticked (Wintex). Keypads 1&2 are in the house, Keypad 3 in Garage. The XP8 expander has 1 zone (zone 9) used as A and...
  6. SgtWilson1

    Setup Bell Box for another are using OP

    You guys might be learning the odd thing from each other - I'm soaking up this info like a sponge! :lol: - I'm reading everything more than twice just to keep up with it. I'm very grateful to you both - Thanks again
  7. SgtWilson1

    Setup Bell Box for another are using OP

    Related to my earlier post http://www.diynot.com/diy/threads/set-up-texecom-premier-elite-48-for-2-areas.424782/#3299886 If I use OP1 (or more than one OP if needed) in the XP8 for the Area B Bell, how do I wire for the 5 wires that are used for the panel bell output using the OPs. Bell and...
  8. SgtWilson1

    Set up Texecom Premier Elite 48 for 2 Areas

    Thanks Guys. I think I follow your tracks. I'll get the extra RKPs etc on order and get on the bench and see how it behaves. For me certainly it's one thing reading it and another thing doing it. I'll come back on this thread if I get stuck. Thanks again.
  9. SgtWilson1

    Set up Texecom Premier Elite 48 for 2 Areas

    Hi Fellas, I have the bench setup for the alarm on the house sussed now (I think) thanks to some really top help from the forum. I originally intended to get the house sorted and then copy the setup with the same panel for the garage and workshops. Then I thought perhaps it could be done...
  10. SgtWilson1

    Wiring 3 SC517/G2 in series and also one stand Texecom 48

    Picking back up on my previous thread http://www.diynot.com/diy/threads/wiring-3-contacts-in-series-to-texecom-48.423284/ I have now purchased the SC517s ready to go. I intend to use the FSL wiring option just want to be sure about the link cutting as the installation instruction shows for 2...
  11. Untitled

    Untitled

  12. Alarm

    Alarm

  13. SgtWilson1

    wiring 3 contacts in series to texecom 48

    Thanks again, Yes these do look a better option. I should have asked you rather the guy that sold them to me :lol: Cheers Mark
  14. SgtWilson1

    wiring 3 contacts in series to texecom 48

    I have changed the configuration of the contacts that I want to use across 3 sets of bifolders (these doors have been by far the biggest headache, thought I had a solution thanks to scott1980 with the Texecom Duel contact and viper but they turned out to be too larger footprint and fouled the...
  15. SgtWilson1

    Best way to Wire Panic Button to Texecom 48 and Ext Klaxon

    Thanks again Mark for your time and information.
  16. SgtWilson1

    Best way to Wire Panic Button to Texecom 48 and Ext Klaxon

    I have 2 panic buttons in series back to the Panel, I do have a spare zone on the expander but have them earmarked for later additions to out buildings. I also have used OP1 for internal sounder (sounding 1 minute in advance of outside bell) and have OP2 earmarked (please see further Q2 below)...
  17. SgtWilson1

    Using 12V Heatmiser UH1 with Neostat-HW stat

    Thank you for your time and your comments; I will pass them on to my electrician
  18. SgtWilson1

    12v Relay to switch 7 30W LED Floods

    That's very re-assuring thanks fro your time and info.
  19. SgtWilson1

    12v Relay to switch 7 30W LED Floods

    Thanks Guys. The RIU-R12 12V Auxiliary Relay looks good Adrian. I had seen an Elmdene one Mark but is it 3 Amp (rather than 5A above). Adrian, will this be ok so switch all 7 through one RIU-R12 ? Much appreciated.
  20. SgtWilson1

    12v Relay to switch 7 30W LED Floods

    I'm looking for a 12V relay that on alarm will turn on Qty 7 30W LED floods (all on the same mains circuit). What rating of switching current will I need? I ask this unsurely as when sourcing the house dimmers for the in ceiling LEDs a 3W led needed about 10W of dimming capability (max 8-10...