    What's all this talk about a spur off a ring only being able to pull 13A? Unfused spurs can pull 26A with a double socket can't they?
  2. A

    pre fab garage plans

    I am having a garage delivered. It will be under 30m2 floor area so that I do not have to have building control issues. Do I need professionally drawn plans for a pre fab for planning permission? Can the company that supplies the garage supply plans? It's from a firm called Pudsey
  3. A

    3 phase from single

    just done it Ta very much
  4. A

    3 phase from single

    What is the cheapest/easiest way to get 3 phase from single phase off a normal domestic supply? There must b something cheaper than buying a genny?
  5. A

    Cast gutters and down pipes

    How easy is it to replace cast iron guttering/down pies/soil pipes with plastic? Someone told me that it's a nightmare to get off as it's so heavy? Would I need scaffolding or just ladders ok?
  6. A

    Sectional garage

    Do I need planning permission for a sectional garage? I've read on a website somewhere that a sectional garage doesn't need it because it is regarded as a portable building and will be under 30m2 and under 70m3. However I'm not sure tat this is still the case.
  7. A

    heater diverter valve

    I've been told the heater diverter valve is at fault with my ford courier, and that is why it won't warm up. Is this the heat control valve on the dash, and if so, is it easy to change?
  8. A

    blowers nto warming up

    Went o see a van today, went for a drive but the blowers stayed cold. Also, the engine temp display didn't seem to get very warm either, and I was out in it for 20 mins. What could be the problem with it? It's a T reg ford courier 1.8D (not turbo) Also the brake warning light came on when...
  9. A

    wire in wall

    Right then, the dotting and dabbing lads have lost my 3 core and earth wire inside a wall for me. The wall is quite thick as it is on the outside wall of a barn, so there is plenty of space for my cable to get lost in. How can I find my cable? I have tried my cable/stud finder on it, but it only...
  10. A

    contactum timer?

    Is there a timer unit that I can fit into a Contactum consumer unit? There are 3 spare ways in the consumer unit.
  11. A

    fcu in bathroom

    It's feeding a 12v fan transformer
  12. A

    fcu in bathroom

    thought so. Thanks for quick reply.
  13. A

    fcu in bathroom

    can put an fcu in a bathroom if it is outside zone 3? it would be up a height of about 2.5m
  14. A

    flickering lights

    Why do low voltage lights flicker when using dimmers if the the dimmers are underloaded by too much?
  15. A

    de rating dimmers for halogen lights.

    Why are dimmers de rated for halogen lights when they are just filament bulbs? I can understand for l.v. halogen when there is a transformer in the cct, but not for mains halogen as normal incandescent bulbs aren't derated. Also, what are the best dimmers for feeding l.v. halogen light fittings...
  16. A

    isdn

    No phones in as yet.
  17. A

    isdn

    I want to put ISDN onto every telephone point in a house (5 points), but the telephone wiring has been "starred"out from the master telephone point. Can I get way with this wiring config or does it HAVE to be daisy chained? This would mean a lot of chopping into new plaster! Can I get away with...
  18. A

    CAT III eqipmentin bathrooms

    If the equipment doesn't incorporate a switch or other means of electrical control or adjustment, then it is allowed to be accessible from a bath or shower, including 230v equipment. So cat II should be allowed above a bath or shower as long as it is IPx4 or above. Is it possibly a case of an...
  19. A

    CAT III eqipmentin bathrooms

    Has there been any new legislation on CAT III equipment in bathrooms? My mate is trying to rent his house out and his NECEIC test has come back failed because of a lack of CAT III equipment in his bathroom. The lights are not above the shower or bath and they are CAT II and enclosed.
  20. A

    Fan isolators in bathrooms

    How can I put a fan isolator in a bathroom when the regs say that there must be no switches in a bathroom that are not the pullcord/waterproof type?